Comparative Determination of the Mechanical Strength of a Transplant from a Tendon of a Semitendinosus Muscle for Plastic Surgery of the Anterior Cruciate Ligament Prepared in Various Ways (Experimental Study)

D. B. Balzhinimaev, I. Mikhaylov, N. Tishkov
{"title":"Comparative Determination of the Mechanical Strength of a Transplant from a Tendon of a Semitendinosus Muscle for Plastic Surgery of the Anterior Cruciate Ligament Prepared in Various Ways (Experimental Study)","authors":"D. B. Balzhinimaev, I. Mikhaylov, N. Tishkov","doi":"10.29413/abs.2019-4.6.23","DOIUrl":null,"url":null,"abstract":"According to modern literature, a sufficient number of studies have been carried out to determine the mechanical strength of transplants from the tendon of the semitendinous and gracilis muscles, the autologous ligament of the patella, the broad fascia, peroneus longus tendon, each of which has unique characteristics, but at present, transplants prepared by original (new) methods are understudied. In the period from November 5 to December 17,2018 we conducted an experimental study to determine the mechanical strength of a transplant from a tendon of a semitendinosus muscle taken from cadaveric material. The transplants were prepared by original and well-known (Graft-Link technique) methods. The experimental study was approved by the Ethics committee of Irkutsk Scientific Center of Surgery and Traumatology. The material for the study was prepared on the basis of the Irkutsk Regional Bureau of Forensic Medical Examination. After sampling the cadaveric material being studied, the main stages of the experimental study were carried out at the materials resistance department of the Irkutsk State Technical University. Studies of the mechanical properties of the transplant were carried out on a Shimadzu testing machine registered in the State Register of Measuring Instruments and approved for use in the Russian Federation. As a result of the study, we obtained the following data. The mechanical strength of the graft obtained from the tendon of the semitendinosus muscle in an original way is on average 607.8 ± 101.2 N/mm. The mechanical strength of the graft obtained from the tendon of the semitendinosus muscle in a traditional manner (Graft-Link technique) is on average 351.8 ± 133.0 N/ mm.","PeriodicalId":6986,"journal":{"name":"Acta Biomedica Scientifica (East Siberian Biomedical Journal)","volume":"11 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Biomedica Scientifica (East Siberian Biomedical Journal)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29413/abs.2019-4.6.23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

According to modern literature, a sufficient number of studies have been carried out to determine the mechanical strength of transplants from the tendon of the semitendinous and gracilis muscles, the autologous ligament of the patella, the broad fascia, peroneus longus tendon, each of which has unique characteristics, but at present, transplants prepared by original (new) methods are understudied. In the period from November 5 to December 17,2018 we conducted an experimental study to determine the mechanical strength of a transplant from a tendon of a semitendinosus muscle taken from cadaveric material. The transplants were prepared by original and well-known (Graft-Link technique) methods. The experimental study was approved by the Ethics committee of Irkutsk Scientific Center of Surgery and Traumatology. The material for the study was prepared on the basis of the Irkutsk Regional Bureau of Forensic Medical Examination. After sampling the cadaveric material being studied, the main stages of the experimental study were carried out at the materials resistance department of the Irkutsk State Technical University. Studies of the mechanical properties of the transplant were carried out on a Shimadzu testing machine registered in the State Register of Measuring Instruments and approved for use in the Russian Federation. As a result of the study, we obtained the following data. The mechanical strength of the graft obtained from the tendon of the semitendinosus muscle in an original way is on average 607.8 ± 101.2 N/mm. The mechanical strength of the graft obtained from the tendon of the semitendinosus muscle in a traditional manner (Graft-Link technique) is on average 351.8 ± 133.0 N/ mm.
半腱肌肌腱移植用于不同制备方法前交叉韧带整形手术机械强度的比较测定(实验研究)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信