{"title":"Pressure gauge network design for leakage detection in water distribution systems using a combination of the pressure residual vector method and the entropy concept","authors":"M. Ebrahimi, Mahmood Reza Shaghaghian, Z. Ghadampour","doi":"10.2166/ws.2023.186","DOIUrl":null,"url":null,"abstract":"\n The present study proposed an algorithm to design a pressure gauge network in a water distribution system by employing the entropy concept in the pressure residual vector method. Firstly, the temporal pattern of water consumption was determined by collecting real-time information through 39 automatic electromechanical water meters. The observational process was performed over 1 year, and hourly statistical parameters were calculated for the log-normal probability density function. Afterwards, imposing the synthetic leakage in each pipe, determining the average entropy of water head variations in the nodes, and performing a combinatorial optimization process, a pressure gauge network (PGN) in a WDS was suggested. The proposed procedure of designing a PGN was tested for both regular and irregular WDS at different leakage parameters (pressure exponents 0.5, 1.0, and 1.5, and emitter coefficient between 0 and 0.8 m3/s). It was observed that the entropy content does not increase significantly after a convincing number of pressure gauges, which can be considered the required number of pressure gauges in the PGN. Furthermore, the monitoring time required to obtain 70% of the entropy content of the water head was about 40 h. However, the time to get 80% of the entropy content had to increase by 80 h, which severely impairs the method's efficiency.","PeriodicalId":17553,"journal":{"name":"Journal of Water Supply Research and Technology-aqua","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2023-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Water Supply Research and Technology-aqua","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/ws.2023.186","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 0

Abstract

The present study proposed an algorithm to design a pressure gauge network in a water distribution system by employing the entropy concept in the pressure residual vector method. Firstly, the temporal pattern of water consumption was determined by collecting real-time information through 39 automatic electromechanical water meters. The observational process was performed over 1 year, and hourly statistical parameters were calculated for the log-normal probability density function. Afterwards, imposing the synthetic leakage in each pipe, determining the average entropy of water head variations in the nodes, and performing a combinatorial optimization process, a pressure gauge network (PGN) in a WDS was suggested. The proposed procedure of designing a PGN was tested for both regular and irregular WDS at different leakage parameters (pressure exponents 0.5, 1.0, and 1.5, and emitter coefficient between 0 and 0.8 m3/s). It was observed that the entropy content does not increase significantly after a convincing number of pressure gauges, which can be considered the required number of pressure gauges in the PGN. Furthermore, the monitoring time required to obtain 70% of the entropy content of the water head was about 40 h. However, the time to get 80% of the entropy content had to increase by 80 h, which severely impairs the method's efficiency.
结合压力残差矢量法和熵的概念设计配水系统的泄漏检测压力表网络
本文提出了一种利用压力残差矢量法中的熵概念设计配水系统压力表网络的算法。首先,通过39台自动机电水表实时采集用水信息,确定用水量的时间格局;在1年的观测过程中,计算对数正态概率密度函数的逐时统计参数。在此基础上,通过对各管道施加综合泄漏,确定各节点水头变化的平均熵,并进行组合优化,提出了水闸系统中的压力表网络。在不同泄漏参数(压力指数为0.5、1.0和1.5,发射器系数为0 ~ 0.8 m3/s)下,对规则和不规则WDS设计PGN的过程进行了测试。我们观察到,在足够的压力表数量后,熵含量并没有显著增加,这可以认为是PGN中所需的压力表数量。获得水头70%的熵值所需的监测时间约为40 h,而获得80%的熵值需要增加80 h的监测时间,严重影响了方法的效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.70
自引率
0.00%
发文量
74
审稿时长
4.5 months
期刊介绍: Journal of Water Supply: Research and Technology - Aqua publishes peer-reviewed scientific & technical, review, and practical/ operational papers dealing with research and development in water supply technology and management, including economics, training and public relations on a national and international level.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信