{"title":"Modified correction-factor analysis of solvent extraction in rectangular membrane modules","authors":"Ho-Ming Yeh","doi":"10.1016/j.jcice.2007.04.008","DOIUrl":null,"url":null,"abstract":"<div><p>The expressions of mass-transfer rate for membrane extraction through a rectangular module have been derived under cocurrent-flow, countercurrent-flow and cross-flow operation based on the modified correction-factor analysis. These expressions are explicit and the results can be readily calculated without using try-and-error method, which should be employed in the conventional correction-factor analysis for designing heat and mass exchangers. The correction factors for both cocurrent-flow and countercurrent-flow operations may be taken as unity when the logarithmic-mean concentration differences are properly selected. For cross-flow operation, the correction factors are function of flow rate, mass-transfer area, distribution coefficient and overall mass-transfer coefficient, and some values of them are given graphically.</p></div>","PeriodicalId":17285,"journal":{"name":"Journal of The Chinese Institute of Chemical Engineers","volume":"38 5","pages":"Pages 385-391"},"PeriodicalIF":0.0000,"publicationDate":"2007-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jcice.2007.04.008","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Chinese Institute of Chemical Engineers","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0368165307000810","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
The expressions of mass-transfer rate for membrane extraction through a rectangular module have been derived under cocurrent-flow, countercurrent-flow and cross-flow operation based on the modified correction-factor analysis. These expressions are explicit and the results can be readily calculated without using try-and-error method, which should be employed in the conventional correction-factor analysis for designing heat and mass exchangers. The correction factors for both cocurrent-flow and countercurrent-flow operations may be taken as unity when the logarithmic-mean concentration differences are properly selected. For cross-flow operation, the correction factors are function of flow rate, mass-transfer area, distribution coefficient and overall mass-transfer coefficient, and some values of them are given graphically.