Analysis of 3-Methyl-4-nitrophenol, A Major Metabolite of Fenitrothion, In Mice Urine Using HPLC

A. S. Surur, Ahungena Alemayyehu, T. Esho
{"title":"Analysis of 3-Methyl-4-nitrophenol, A Major Metabolite of Fenitrothion, In Mice Urine Using HPLC","authors":"A. S. Surur, Ahungena Alemayyehu, T. Esho","doi":"10.5530/PHM.2015.6.4","DOIUrl":null,"url":null,"abstract":"Introduction: 3-methyl-4-nitrophenol is a major metabolite of fenitrothion and is considered as a potential risk to public health owning to its genotoxicity and carcinogenicity. Objective: To develop and validate an HPLC method for the quantification of 3-methyl-4-nitrophenol in urine. Methods: A sample of mice urine was collected following the administration of fenitrothion solution through oral gavage and subsequently, 3-methyl-4-nitrophenol was extracted using a simple liquid-liquid extraction method. The newly developed method uses acetonitrile: water 60:40 mobile phase at 270 nm with a flow rate of 1 mL/min HPLC condition. An optimization to a previously used extraction method was made by using ethyl acetate instead of acetonitrile to avoid extraction of water-soluble components of urine other than 3-methyl- 4-nitrophenol. The developed method was validated using the ICH guideline for the validation of analytical procedures. Accordingly, the selectivity, linearity, limit of detection and quantification, accuracy, precision, extraction efficacy, robustness and stability of the method was determined. Results: All of the validation parameters showed that the method is valid for the determination of 3-methyl-4-nitrophenol in urine sample. Using this method it was possible to detect low concentration of 3-methyl-4-nitrophenol in urine samples down to 0.87 μg/mL. Conclusion: The sample was analyzed with this validated method and the respective concentration of the 3-methyl-4-nitrophenol was found to be 31.11 μg/mL. Accordingly, 10.37% of the total fenitrothion administered to mice was found metabolized into 3-methyl-4-nitrophenol. The HPLC retention time for 3-methyl-4-nitrophenol was 2.81 minutes. Key words: Fenitrothion, 3-methyl-4-nitrophenol, HPLC, Metabolites, Method development, Validation.","PeriodicalId":19960,"journal":{"name":"Pharmaceutical Methods","volume":"22 1","pages":"35-41"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutical Methods","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5530/PHM.2015.6.4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: 3-methyl-4-nitrophenol is a major metabolite of fenitrothion and is considered as a potential risk to public health owning to its genotoxicity and carcinogenicity. Objective: To develop and validate an HPLC method for the quantification of 3-methyl-4-nitrophenol in urine. Methods: A sample of mice urine was collected following the administration of fenitrothion solution through oral gavage and subsequently, 3-methyl-4-nitrophenol was extracted using a simple liquid-liquid extraction method. The newly developed method uses acetonitrile: water 60:40 mobile phase at 270 nm with a flow rate of 1 mL/min HPLC condition. An optimization to a previously used extraction method was made by using ethyl acetate instead of acetonitrile to avoid extraction of water-soluble components of urine other than 3-methyl- 4-nitrophenol. The developed method was validated using the ICH guideline for the validation of analytical procedures. Accordingly, the selectivity, linearity, limit of detection and quantification, accuracy, precision, extraction efficacy, robustness and stability of the method was determined. Results: All of the validation parameters showed that the method is valid for the determination of 3-methyl-4-nitrophenol in urine sample. Using this method it was possible to detect low concentration of 3-methyl-4-nitrophenol in urine samples down to 0.87 μg/mL. Conclusion: The sample was analyzed with this validated method and the respective concentration of the 3-methyl-4-nitrophenol was found to be 31.11 μg/mL. Accordingly, 10.37% of the total fenitrothion administered to mice was found metabolized into 3-methyl-4-nitrophenol. The HPLC retention time for 3-methyl-4-nitrophenol was 2.81 minutes. Key words: Fenitrothion, 3-methyl-4-nitrophenol, HPLC, Metabolites, Method development, Validation.
用高效液相色谱法分析小鼠尿液中非硝硫磷主要代谢物3-甲基-4-硝基苯酚的含量
简介:3-甲基-4-硝基苯酚是非硝硫磷的主要代谢物,由于其遗传毒性和致癌性,被认为对公众健康具有潜在风险。目的:建立并验证尿中3-甲基-4-硝基苯酚的高效液相色谱测定方法。方法:小鼠灌胃非硝硫磷溶液后取尿液,采用简单液液萃取法提取3-甲基-4-硝基苯酚。新方法采用乙腈:水60:40流动相,流速为1 mL/min,液相色谱条件为270 nm。以乙酸乙酯代替乙腈,对原有的提取方法进行了优化,避免了提取尿液中除3-甲基- 4-硝基酚外的水溶性成分。采用ICH分析方法验证指南对所开发的方法进行了验证。对该方法的选择性、线性度、检出限和定量限、准确度、精密度、提取效果、稳健性和稳定性进行了评价。结果:所有验证参数均表明该方法对尿中3-甲基-4-硝基苯酚的测定是有效的。该方法可检测尿样中3-甲基-4-硝基苯酚低至0.87 μg/mL。结论:3-甲基-4-硝基苯酚的检测浓度为31.11 μg/mL。相应的,10.37%的老鼠被发现被代谢成3-甲基-4-硝基苯酚。3-甲基-4-硝基苯酚的HPLC保留时间为2.81 min。关键词:非硝硫磷,3-甲基-4-硝基苯酚,高效液相色谱,代谢物,方法开发,验证
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信