{"title":"How Useful is an Integrated SPECT/CT in Clinical Setting and Research?: Evaluation of a Low Radiation Dose 4 Slice System §","authors":"T. Belhocine, I. Rachinsky, C. Akincioglu, S. Gambhir, B. Wilcox, W. Vezina, L. Stitt, A. Driedger, J. Urbain","doi":"10.2174/1874347100802010080","DOIUrl":null,"url":null,"abstract":"Hybrid imaging is becoming a popular technology in nuclear medicine. We have evaluated the added value of an integrated SPECT/low-dose multislice CT over conventional planar/SPECT nuclear imaging. Phantom and clinical studies were performed on the Infinia™ Hawkeye™ 4 slice (HWK-4) with an upgraded software package (Xeleris 2.05v) from GE Heatlthcare to assess 1) the benefit of CT for contrast-resolution, attenuation correction, and anatomic localisation; 2) the impact of hybrid imaging in 456 consecutive patients in a clinical setting. SPECT/CT data were compared to conventional planar/SPECT data and correlated to clinical, biochemical, morphological imaging, angiography, and pathology findings. SPECT/CT was well tolerated by the patients with minimal CT irradiation dose (< 2mSv). HWK-4 provided useful attenuation correction for its routine use in MPI and accurate anatomic localisation of physiological and pathological foci in 99m Tc-RBC, 99m Tc-HMPAO-WBC, 131/123 I-MIBG, Octreoscan ® , and 67 Ga studies. Low-dose multislice CT also helped detect gross morphological abnormalities. Hybrid imaging had a significant impact in ProstaScint ® and parathyroid imaging for image-guided intervention. In bone imaging and differentiated thyroid cancers, SPECT/CT was able to clarify equivocal findings from planar whole-body scan. SPECT/CT was also found useful to precisely localize sentinel lymph nodes. Research protocols are being evaluated for half-time acquisition with resolution recovery and quantification of tracer distribution. SPECT/low-dose multislice CT has been successfully implemented in routine clinical practice. CT provided added value for effective attenuation correction and accurate anatomic localisation of disease with an impact on patient management.","PeriodicalId":90366,"journal":{"name":"The open medical imaging journal","volume":"52 1","pages":"80-108"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The open medical imaging journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874347100802010080","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Hybrid imaging is becoming a popular technology in nuclear medicine. We have evaluated the added value of an integrated SPECT/low-dose multislice CT over conventional planar/SPECT nuclear imaging. Phantom and clinical studies were performed on the Infinia™ Hawkeye™ 4 slice (HWK-4) with an upgraded software package (Xeleris 2.05v) from GE Heatlthcare to assess 1) the benefit of CT for contrast-resolution, attenuation correction, and anatomic localisation; 2) the impact of hybrid imaging in 456 consecutive patients in a clinical setting. SPECT/CT data were compared to conventional planar/SPECT data and correlated to clinical, biochemical, morphological imaging, angiography, and pathology findings. SPECT/CT was well tolerated by the patients with minimal CT irradiation dose (< 2mSv). HWK-4 provided useful attenuation correction for its routine use in MPI and accurate anatomic localisation of physiological and pathological foci in 99m Tc-RBC, 99m Tc-HMPAO-WBC, 131/123 I-MIBG, Octreoscan ® , and 67 Ga studies. Low-dose multislice CT also helped detect gross morphological abnormalities. Hybrid imaging had a significant impact in ProstaScint ® and parathyroid imaging for image-guided intervention. In bone imaging and differentiated thyroid cancers, SPECT/CT was able to clarify equivocal findings from planar whole-body scan. SPECT/CT was also found useful to precisely localize sentinel lymph nodes. Research protocols are being evaluated for half-time acquisition with resolution recovery and quantification of tracer distribution. SPECT/low-dose multislice CT has been successfully implemented in routine clinical practice. CT provided added value for effective attenuation correction and accurate anatomic localisation of disease with an impact on patient management.
综合SPECT/CT在临床和研究中的作用如何?低辐射剂量4片系统的评价
混合成像技术正在成为核医学领域的热门技术。我们已经评估了集成SPECT/低剂量多层CT比传统平面/SPECT核成像的附加价值。幻影和临床研究是在Infinia™Hawkeye™4切片(HWK-4)上进行的,使用GE healthcare的升级软件包(Xeleris 2.05v)来评估1)CT在对比度分辨率、衰减校正和解剖定位方面的优势;2)混合成像对456例连续临床患者的影响。将SPECT/CT数据与常规平面/SPECT数据进行比较,并与临床、生化、形态成像、血管造影和病理结果相关联。最小CT照射剂量(< 2mSv)的患者对SPECT/CT耐受良好。在99m Tc-RBC、99m tc - hpao - wbc、131/123 I-MIBG、octrescan®和67ga研究中,HWK-4为MPI的常规使用提供了有用的衰减校正,并对生理和病理病灶进行了准确的解剖定位。低剂量多层螺旋CT也有助于检测大体形态异常。混合成像对ProstaScint®和甲状旁腺成像在图像引导下的干预有显著影响。在骨成像和分化的甲状腺癌中,SPECT/CT能够澄清平面全身扫描的模棱两可的发现。SPECT/CT也有助于精确定位前哨淋巴结。研究方案正在评估半时间采集与分辨率恢复和量化示踪剂分布。SPECT/低剂量多层螺旋CT已成功应用于常规临床。CT为有效的衰减校正和准确的疾病解剖定位提供了附加价值,对患者管理有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信