Diffuse optical tomography to monitor the photocoagulation front during interstitial photothermal therapy: Numerical simulations and measurements in tissue-simulating phantoms

Jie He, B. Wilson, D. Piao, R. Weersink
{"title":"Diffuse optical tomography to monitor the photocoagulation front during interstitial photothermal therapy: Numerical simulations and measurements in tissue-simulating phantoms","authors":"Jie He, B. Wilson, D. Piao, R. Weersink","doi":"10.1515/plm-2014-0011","DOIUrl":null,"url":null,"abstract":"Abstract Near-infrared interstitial photothermal therapy (PTT) is currently undergoing clinical trials as an alternative to watchful waiting or radical treatments in patients with low/intermediate-risk focal prostate cancer. Currently, magnetic resonance imaging (MRI)-based thermography is used to monitor thermal energy delivery and determine indirectly the completeness of the target tumor destruction while avoiding damage to adjacent normal tissues, particularly the rectal wall. As an alternative, transrectal diffuse optical tomography (TRDOT) is being developed to image directly the photocoagulation boundary based on the changes in tissue optical properties, particularly scattering. An established diffusion-theory finite-element software platform was used to perform forward simulations to determine the sensitivity of changes in the optical signal resulting from a growing coagulated lesion with optical scattering contrast, for varying light source-detector separations in both longitudinal and transverse imaging geometries. The simulations were validated experimentally in tissue-simulating phantoms using an existing continuous-wave TRDOT system, in a configuration that is representative of one potential intended clinical use. This provides critical guidance for the optimum design of the transrectal applicator probe, in terms of achieving maximum sensitivity to the presence of the coagulation boundary and, consequently, the highest accuracy in determining the boundary location relative to the rectal wall.","PeriodicalId":20126,"journal":{"name":"Photonics & Lasers in Medicine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photonics & Lasers in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/plm-2014-0011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Abstract Near-infrared interstitial photothermal therapy (PTT) is currently undergoing clinical trials as an alternative to watchful waiting or radical treatments in patients with low/intermediate-risk focal prostate cancer. Currently, magnetic resonance imaging (MRI)-based thermography is used to monitor thermal energy delivery and determine indirectly the completeness of the target tumor destruction while avoiding damage to adjacent normal tissues, particularly the rectal wall. As an alternative, transrectal diffuse optical tomography (TRDOT) is being developed to image directly the photocoagulation boundary based on the changes in tissue optical properties, particularly scattering. An established diffusion-theory finite-element software platform was used to perform forward simulations to determine the sensitivity of changes in the optical signal resulting from a growing coagulated lesion with optical scattering contrast, for varying light source-detector separations in both longitudinal and transverse imaging geometries. The simulations were validated experimentally in tissue-simulating phantoms using an existing continuous-wave TRDOT system, in a configuration that is representative of one potential intended clinical use. This provides critical guidance for the optimum design of the transrectal applicator probe, in terms of achieving maximum sensitivity to the presence of the coagulation boundary and, consequently, the highest accuracy in determining the boundary location relative to the rectal wall.
弥漫性光学断层扫描在间质光热治疗期间监测光凝前沿:组织模拟幻象中的数值模拟和测量
近红外间质光热疗法(PTT)目前正在进行临床试验,作为低/中危局灶性前列腺癌患者观察等待或根治性治疗的替代方案。目前,基于磁共振成像(MRI)的热成像用于监测热能传递,并间接确定目标肿瘤破坏的完整性,同时避免损伤邻近的正常组织,特别是直肠壁。作为一种替代方案,经直肠弥漫性光学断层扫描(TRDOT)正在发展,根据组织光学特性的变化,特别是散射,直接成像光凝边界。利用已建立的扩散理论有限元软件平台进行正演模拟,以确定在纵向和横向成像几何形状中不同光源-探测器距离下,由不断增长的凝固病变引起的光信号变化对光学散射对比度的灵敏度。在组织模拟幻影中,使用现有的连续波TRDOT系统进行了模拟实验验证,其配置代表了一种潜在的预期临床应用。这为经直肠穿刺探针的优化设计提供了关键的指导,以实现对凝血边界存在的最大灵敏度,从而在确定相对于直肠壁的边界位置方面具有最高的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信