A low power and convenient bio-impedance monitor, and its application to respiration monitoring

Seulki Lee, C. Agell, Salvatore Polito, R. Vullers, J. Penders
{"title":"A low power and convenient bio-impedance monitor, and its application to respiration monitoring","authors":"Seulki Lee, C. Agell, Salvatore Polito, R. Vullers, J. Penders","doi":"10.1145/2534088.2534091","DOIUrl":null,"url":null,"abstract":"A low power and convenient bio-impedance monitor, which relies on a proprietary ASIC to achieve low power performance, is shown. It can be used in several bio-impedance applications, especially in continuous and wearable applications thanks to its compact form factor and long battery life time. In this paper, we demonstrate its performance for respiration monitoring. The result is compared with that of the reference system, showing a high correlation factor of 0.91.","PeriodicalId":91386,"journal":{"name":"Proceedings Wireless Health ... [electronic resource]. Wireless Health (Conference)","volume":"25 3 1","pages":"13:1-13:2"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings Wireless Health ... [electronic resource]. Wireless Health (Conference)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2534088.2534091","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A low power and convenient bio-impedance monitor, which relies on a proprietary ASIC to achieve low power performance, is shown. It can be used in several bio-impedance applications, especially in continuous and wearable applications thanks to its compact form factor and long battery life time. In this paper, we demonstrate its performance for respiration monitoring. The result is compared with that of the reference system, showing a high correlation factor of 0.91.
一种低功耗、方便的生物阻抗监测仪,及其在呼吸监测中的应用
展示了一种低功耗、方便的生物阻抗监测仪,该监测仪依靠专用的ASIC实现低功耗性能。由于其紧凑的外形和较长的电池寿命,它可以用于多种生物阻抗应用,特别是在连续和可穿戴应用中。在本文中,我们证明了它在呼吸监测中的性能。结果与参考系统进行了比较,相关系数为0.91。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信