Derivaldo Moura Gois Filho, V. T. Gois-Santos, Ronaldo S. Silva, A. C. Marqueti, A. Cortes, C. L. Trento
{"title":"Evaluation of sealing between abutment and inner connection of cone morse dental implant","authors":"Derivaldo Moura Gois Filho, V. T. Gois-Santos, Ronaldo S. Silva, A. C. Marqueti, A. Cortes, C. L. Trento","doi":"10.11606/ISSN.2357-8041.CLRD.2018.147797","DOIUrl":null,"url":null,"abstract":"Introduction: The adaptation of prostheses fixed over implants involves biomechanical aspects that are directly associated with treatment success. Objective: The aim of this in vitro study was to evaluate the presence of microgaps in the abutment/inner connection interface of cone morse dental implants. Materials and methods: Two groups of implants were analyzed. The first group (n = 16) employed single-manufacturer dental implants and abutments, whereas the second group (n = 16) combined multi-manufacturer materials. The sets were analyzed through scanning electron microscopy, wherein microgaps between the implant connection and the abutment were observed. Results: Group 1 had an average microgap of 5.69 μm (SD ± 8.46 μm). Group 2 had an average microgap of 1.24 μm (SD ± 0.44 μm). A significant difference was found between the two groups (p = 0.002). Conclusion: Within the limitations of this study, results suggest that the group formed by multi-manufacturer implants and abutments (group 2) had smaller microgap values, and, therefore, a higher in vitro adaptation of components. \nDESCRIPTORS | Dental Implants; Dental Abutments; Scanning Electron Microscopy.","PeriodicalId":10204,"journal":{"name":"Clinical and Laboratorial Research in Dentistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Laboratorial Research in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11606/ISSN.2357-8041.CLRD.2018.147797","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Introduction: The adaptation of prostheses fixed over implants involves biomechanical aspects that are directly associated with treatment success. Objective: The aim of this in vitro study was to evaluate the presence of microgaps in the abutment/inner connection interface of cone morse dental implants. Materials and methods: Two groups of implants were analyzed. The first group (n = 16) employed single-manufacturer dental implants and abutments, whereas the second group (n = 16) combined multi-manufacturer materials. The sets were analyzed through scanning electron microscopy, wherein microgaps between the implant connection and the abutment were observed. Results: Group 1 had an average microgap of 5.69 μm (SD ± 8.46 μm). Group 2 had an average microgap of 1.24 μm (SD ± 0.44 μm). A significant difference was found between the two groups (p = 0.002). Conclusion: Within the limitations of this study, results suggest that the group formed by multi-manufacturer implants and abutments (group 2) had smaller microgap values, and, therefore, a higher in vitro adaptation of components.
DESCRIPTORS | Dental Implants; Dental Abutments; Scanning Electron Microscopy.