Comparative Evaluation of heat-inactivated ABO isoagglutinin titers with solid-phase red cell adhesion titers

S. Ranjan, P. Pandey, D. Setya, S. Kumari
{"title":"Comparative Evaluation of heat-inactivated ABO isoagglutinin titers with solid-phase red cell adhesion titers","authors":"S. Ranjan, P. Pandey, D. Setya, S. Kumari","doi":"10.4103/gjtm.gjtm_65_21","DOIUrl":null,"url":null,"abstract":"Background and Objectives: Measurement of actual concentration of IgG requires methods like heat inactivation (HI) of serum. This study was aimed at comparing of heat-treated ABO titers performed by conventional test tube technique (CTT) and column agglutination technique (CAT) with hemagglutination (HA)/solid-phase red cell adherence (SPRCA). Methods: This was a prospective, observational study conducted between October 2019 and March 2020. All consecutive A, B, and O group donors who gave consent for participation in the project were included. All samples were tested by CTT and CAT before and after HI (post DTT treatment performed by CTT [pCTT] and post DTT treatment performed by CAT [pCAT]) and with HA/SPRCA. Results: A total of 300 donors were included: 100 each with A, B, and O blood groups. For group O, IgG titers were higher than IgM titers among group O, whereas that among group A and group B, IgM titer was found to be higher than IgG titer by both HA/SPRCA and pCTT. The titer values among all the three blood groups were highest when the test was performed by pCAT, though the results of pCTT and SPRCA, pCTT, and pCAT were significant in group O donors. For groups A and B, results of pCTT and pCAT, pCAT, and HA/SPRCA were found to be statistically significant. Conclusion: Results obtained by HA/SPRCA were closer to pCTT, with respect to time consumption, expertise required, and lack of inter-observer variation. Titers obtained by pCAT were higher in comparison to pCTT obviously due to its relative higher sensitivity. Hence, these methods cannot be used interchangeably.","PeriodicalId":52961,"journal":{"name":"Global Journal of Transfusion Medicine","volume":"2013 1","pages":"54 - 59"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Journal of Transfusion Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/gjtm.gjtm_65_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and Objectives: Measurement of actual concentration of IgG requires methods like heat inactivation (HI) of serum. This study was aimed at comparing of heat-treated ABO titers performed by conventional test tube technique (CTT) and column agglutination technique (CAT) with hemagglutination (HA)/solid-phase red cell adherence (SPRCA). Methods: This was a prospective, observational study conducted between October 2019 and March 2020. All consecutive A, B, and O group donors who gave consent for participation in the project were included. All samples were tested by CTT and CAT before and after HI (post DTT treatment performed by CTT [pCTT] and post DTT treatment performed by CAT [pCAT]) and with HA/SPRCA. Results: A total of 300 donors were included: 100 each with A, B, and O blood groups. For group O, IgG titers were higher than IgM titers among group O, whereas that among group A and group B, IgM titer was found to be higher than IgG titer by both HA/SPRCA and pCTT. The titer values among all the three blood groups were highest when the test was performed by pCAT, though the results of pCTT and SPRCA, pCTT, and pCAT were significant in group O donors. For groups A and B, results of pCTT and pCAT, pCAT, and HA/SPRCA were found to be statistically significant. Conclusion: Results obtained by HA/SPRCA were closer to pCTT, with respect to time consumption, expertise required, and lack of inter-observer variation. Titers obtained by pCAT were higher in comparison to pCTT obviously due to its relative higher sensitivity. Hence, these methods cannot be used interchangeably.
热灭活ABO异凝集素滴度与固相红细胞粘附滴度的比较评价
背景与目的:IgG实际浓度的测定需要采用血清热失活(HI)等方法。本研究旨在比较传统试管技术(CTT)和柱凝集技术(CAT)与血凝(HA)/固相红细胞粘附(SPRCA)测定的热处理ABO滴度。方法:这是一项前瞻性观察性研究,于2019年10月至2020年3月进行。所有连续同意参与该项目的A、B、O组捐赠者均被纳入。所有样品在HI前后(DTT后由CTT [pCTT]处理,DTT后由CAT [pCAT]处理)和HA/SPRCA检测CTT和CAT。结果:共纳入献血者300人,其中A、B、O型各100人。在O组中,IgG滴度高于IgM滴度,而在A组和B组中,HA/SPRCA和pCTT均发现IgM滴度高于IgG滴度。尽管pCTT和SPRCA、pCTT和pCAT的结果在O组献血者中具有显著性,但采用pCAT检测时,三种血型的滴度值均最高。A、B组pCTT、pCAT、HA/SPRCA结果均有统计学意义。结论:HA/SPRCA获得的结果在耗时、所需专业知识和缺乏观察者间差异方面更接近pCTT。pCAT法测定的滴度明显高于pCTT法,这是由于其相对较高的灵敏度。因此,这些方法不能互换使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
25
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信