The Step of Partial Discharge Pattern Recognition Using Fuzzy Logic

Lury Amatullah Lumba, U. Khayam, Lunnetta Safura Lumba, Claysius Dewanata Widjaja
{"title":"The Step of Partial Discharge Pattern Recognition Using Fuzzy Logic","authors":"Lury Amatullah Lumba, U. Khayam, Lunnetta Safura Lumba, Claysius Dewanata Widjaja","doi":"10.1109/ICHVEPS47643.2019.9011078","DOIUrl":null,"url":null,"abstract":"This paper discusses the method of detecting and measuring Partial Discharge using fuzzy logic. Most of insulation failures indicate Partial Discharge (PD) activity prior to the fault. Several cases show PD is the indication of insulation aging and also the cause of insulation deterioration. Further effect of PD is accelerating the insulation breakdown to occur. Many researches conclude that monitoring is important to be performed. Monitoring PD can avoid the high voltage equipment experience an early aging. Detecting PD is necessary to know the amount of PD and understand the condition of the equipment. The measurements are made using electrical methods for air insulation. The measurement results will be conducted on three level of voltages, and the results will be compared to determine the effectiveness of fuzzy logic in determining the state of the apparatus and monitoring partial discharge.","PeriodicalId":6677,"journal":{"name":"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)","volume":"1 1","pages":"035-039"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVEPS47643.2019.9011078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper discusses the method of detecting and measuring Partial Discharge using fuzzy logic. Most of insulation failures indicate Partial Discharge (PD) activity prior to the fault. Several cases show PD is the indication of insulation aging and also the cause of insulation deterioration. Further effect of PD is accelerating the insulation breakdown to occur. Many researches conclude that monitoring is important to be performed. Monitoring PD can avoid the high voltage equipment experience an early aging. Detecting PD is necessary to know the amount of PD and understand the condition of the equipment. The measurements are made using electrical methods for air insulation. The measurement results will be conducted on three level of voltages, and the results will be compared to determine the effectiveness of fuzzy logic in determining the state of the apparatus and monitoring partial discharge.
基于模糊逻辑的局部放电模式识别步骤
本文讨论了用模糊逻辑检测和测量局部放电的方法。大多数绝缘故障在故障发生之前就预示着局部放电(PD)活动。几个案例表明,局部放电是绝缘老化的标志,也是绝缘劣化的原因。PD的进一步作用是加速绝缘击穿的发生。许多研究得出结论,监测是很重要的。监测局部放电可以避免高压设备过早老化。检测PD是了解PD量和了解设备状况的必要手段。使用电气方法对空气绝缘进行测量。测量结果将在三个电压水平上进行,并将结果进行比较,以确定模糊逻辑在确定设备状态和监测局部放电方面的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信