Analysis of Heat Recovery System Performance Using a Serpentine-Type Heat Exchanger on Water Heater with Fins Number Variation

I Gusti Agung Gede Kusuma Artha, M. Sucipta, Hendra Wijaksana
{"title":"Analysis of Heat Recovery System Performance Using a Serpentine-Type Heat Exchanger on Water Heater with Fins Number Variation","authors":"I Gusti Agung Gede Kusuma Artha, M. Sucipta, Hendra Wijaksana","doi":"10.37275/nasetjournal.v3i2.34","DOIUrl":null,"url":null,"abstract":"The water heater is a common facility found in hotels or homes. There are alternative ways to do this besides using water heaters on the market, namely by utilizing the heat generated by the compressor and which will be discharged through the condenser, by adding a heat recovery system to the air conditioning unit. These research tests were carried out on variations of the serpentine-type heat exchanger with variations in the number of fin plates on the performance of the heat recovery system and on the split air conditioner. This research is an experimental study on a serpentine-type heat exchanger. Tests were carried out on a variety of heat exchangers with variations in the number of fin plates combined with a heat recovery system on a split AC. The independent variables in this study were three variations of the placement of the fin plate on the serpentine-type coil and the setting of the output air of the AC evaporator. Enthalpy values, refrigeration effects, compressor work, condenser, and coefficient of performance (COP) are calculated and presented in tables and graphs. The results of the performance of the heat recovery system obtained variations in the setting of the air burst coming out of the evaporator 24ºC has the highest COP value. The use of a heat recovery system can increase COP. With variations in the number of fin plates in a heat recovery system with a serpentine heat exchanger, the use of 5 fin plates has the hottest water temperature compared to the use of 3 fin plates and 1 fin plate.","PeriodicalId":19046,"journal":{"name":"Natural Sciences Engineering and Technology Journal","volume":"32 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Natural Sciences Engineering and Technology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37275/nasetjournal.v3i2.34","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The water heater is a common facility found in hotels or homes. There are alternative ways to do this besides using water heaters on the market, namely by utilizing the heat generated by the compressor and which will be discharged through the condenser, by adding a heat recovery system to the air conditioning unit. These research tests were carried out on variations of the serpentine-type heat exchanger with variations in the number of fin plates on the performance of the heat recovery system and on the split air conditioner. This research is an experimental study on a serpentine-type heat exchanger. Tests were carried out on a variety of heat exchangers with variations in the number of fin plates combined with a heat recovery system on a split AC. The independent variables in this study were three variations of the placement of the fin plate on the serpentine-type coil and the setting of the output air of the AC evaporator. Enthalpy values, refrigeration effects, compressor work, condenser, and coefficient of performance (COP) are calculated and presented in tables and graphs. The results of the performance of the heat recovery system obtained variations in the setting of the air burst coming out of the evaporator 24ºC has the highest COP value. The use of a heat recovery system can increase COP. With variations in the number of fin plates in a heat recovery system with a serpentine heat exchanger, the use of 5 fin plates has the hottest water temperature compared to the use of 3 fin plates and 1 fin plate.
带翅片数变化的蛇形换热器热水器热回收系统性能分析
热水器是酒店或家庭中常见的设施。除了使用市场上的热水器外,还有其他方法可以做到这一点,即利用压缩机产生的热量并通过冷凝器排出,通过在空调机组中添加热回收系统。这些研究试验是在蛇形换热器随翅片数量的变化对热回收系统和分体式空调性能的影响上进行的。本研究是对蛇纹石式换热器的实验研究。在分体式空调上,对不同翅片数量的换热器进行了试验,并结合了热回收系统。本研究的自变量是蛇形盘管上翅片位置的三种变化以及空调蒸发器输出空气的设置。计算焓值、制冷效果、压缩机功、冷凝器和性能系数(COP),并用图表表示。热回收系统的性能结果表明,在蒸发器出风温度为24℃时COP值最高。使用热回收系统可以提高COP。在带有蛇形换热器的热回收系统中,随着翅片数量的变化,与使用3个翅片和1个翅片相比,使用5个翅片具有最高的水温。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信