The role of dynamic and diffusion weighted magnetic resonance imaging in differentiating malignant and benign portal vein thrombosis

M. Koç
{"title":"The role of dynamic and diffusion weighted magnetic resonance imaging in differentiating malignant and benign portal vein thrombosis","authors":"M. Koç","doi":"10.5455/JTOMC.2017.11.145","DOIUrl":null,"url":null,"abstract":"Aim: The aim of this study was to evaluate the role of dynamic and diffusion-weighted (DW) magnetic resonance imaging (MRI) in the differentiation of benign from malignant thrombus in patients diagnosed with portal vein thrombosis. Material and Methods: The test results of a total of 56 patients were analyzed in this study, of which 27 with benign and 29 with malignant thrombus on abdomen dynamic and DW-MRI. The b-value of DW-MRI was 400 and 1,000 mm2/sec. ADC of portal vein thrombosis was measured. Characteristics of the DW-MRI signal were recorded. Contrast imaging of the thrombus was performed. The diameter of the portal vein was measured. A comparison of the ADC values between the malignant and benign groups was made using the Mann-Whitney U test. Results: The mean ADC values of benign thrombus were calculated as 1.03±0.27 x 10-3 mm2/sec for b400, and 1.01±0.23 x 10-3 mm2/sec for b1000. The mean ADC values were calculated as 0.93±0.13 x 10-3 mm2/sec for b400 and 0.88±0.26 x 10-3 mm2/sec for b1000 for malignant thrombus. No statistically significant difference was found between the groups (p=0.778). Malignant thrombus was reported to have higher signal intensity compared to the benign cases in DW-MRI. Arterial mild contrasting was found with malignant thrombus with dynamic MRI on subtraction images. Contrast media uptake was not seen in the benign group. Statistically significant difference was found between the groups for portal vein diameter (p","PeriodicalId":17427,"journal":{"name":"Journal of Turgut Ozal Medical Center","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Turgut Ozal Medical Center","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5455/JTOMC.2017.11.145","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The aim of this study was to evaluate the role of dynamic and diffusion-weighted (DW) magnetic resonance imaging (MRI) in the differentiation of benign from malignant thrombus in patients diagnosed with portal vein thrombosis. Material and Methods: The test results of a total of 56 patients were analyzed in this study, of which 27 with benign and 29 with malignant thrombus on abdomen dynamic and DW-MRI. The b-value of DW-MRI was 400 and 1,000 mm2/sec. ADC of portal vein thrombosis was measured. Characteristics of the DW-MRI signal were recorded. Contrast imaging of the thrombus was performed. The diameter of the portal vein was measured. A comparison of the ADC values between the malignant and benign groups was made using the Mann-Whitney U test. Results: The mean ADC values of benign thrombus were calculated as 1.03±0.27 x 10-3 mm2/sec for b400, and 1.01±0.23 x 10-3 mm2/sec for b1000. The mean ADC values were calculated as 0.93±0.13 x 10-3 mm2/sec for b400 and 0.88±0.26 x 10-3 mm2/sec for b1000 for malignant thrombus. No statistically significant difference was found between the groups (p=0.778). Malignant thrombus was reported to have higher signal intensity compared to the benign cases in DW-MRI. Arterial mild contrasting was found with malignant thrombus with dynamic MRI on subtraction images. Contrast media uptake was not seen in the benign group. Statistically significant difference was found between the groups for portal vein diameter (p
动态和扩散加权磁共振成像在鉴别门静脉血栓形成中的作用
目的:本研究的目的是评估动态和扩散加权(DW)磁共振成像(MRI)在诊断为门静脉血栓患者的良恶性血栓鉴别中的作用。材料与方法:本研究对56例患者的腹部动态及DW-MRI检查结果进行分析,其中良性血栓27例,恶性血栓29例。DW-MRI b值分别为400和1000 mm2/sec。测量门静脉血栓形成ADC。记录DW-MRI信号特征。对血栓进行对比成像。测量门静脉直径。采用Mann-Whitney U检验比较良性组和恶性组的ADC值。结果:b400的良性血栓ADC平均值为1.03±0.27 × 10-3 mm2/sec, b1000的平均值为1.01±0.23 × 10-3 mm2/sec。恶性血栓b400的平均ADC值为0.93±0.13 x 10-3 mm2/sec, b1000的平均ADC值为0.88±0.26 x 10-3 mm2/sec。两组间差异无统计学意义(p=0.778)。据报道,恶性血栓在DW-MRI上的信号强度高于良性病例。动态MRI减影图像显示动脉轻度对比与恶性血栓。良性组未见造影剂摄取。门静脉直径组间差异有统计学意义(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信