Ashok Kumar, Shoni Sk, M. Dahiya, R. Kumar, A. Yadav, Kumar, H. S. Chaudhary
{"title":"Development and Validation of Liquid Chromatography (RP-HPLC)Methodology for Estimation of Efonidipine HCl Ethanolate (EFD)","authors":"Ashok Kumar, Shoni Sk, M. Dahiya, R. Kumar, A. Yadav, Kumar, H. S. Chaudhary","doi":"10.4172/2153-2435.1000547","DOIUrl":null,"url":null,"abstract":"A Reversed Phase High Performance Liquid Chromatographic (RP-HPLC) method using symmetry C18, 5.0 mm column was developed for the determination of Efonidipine Hydrochloride Ethanolate (EFD). The mobile phase acetonitrile and water ratio was selected 85: 15 via flow rate were 0.8 mL/min and elution was monitored at 254 nm. Response was a linear function of concentration over the range 20-140 μg/ml (R2=0.9994) and the limits of detection was 681.83 ng/ml. The limit of quantification was 2.06 μg/ml. The coefficient of variation for intra-assay and inter-assay precision was less than or equal to 1.5% and the accuracy was 104.0-105.0% and method was validated accordance with International Conference on Harmonization (ICH) guidelines to check content uniformity. In this lieu, a simple and rapid with good accuracy precision validated method is developed which is applicable in quality-estimation, in-future.","PeriodicalId":19833,"journal":{"name":"Pharmaceutica Analytica Acta","volume":"5 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutica Analytica Acta","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2153-2435.1000547","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
A Reversed Phase High Performance Liquid Chromatographic (RP-HPLC) method using symmetry C18, 5.0 mm column was developed for the determination of Efonidipine Hydrochloride Ethanolate (EFD). The mobile phase acetonitrile and water ratio was selected 85: 15 via flow rate were 0.8 mL/min and elution was monitored at 254 nm. Response was a linear function of concentration over the range 20-140 μg/ml (R2=0.9994) and the limits of detection was 681.83 ng/ml. The limit of quantification was 2.06 μg/ml. The coefficient of variation for intra-assay and inter-assay precision was less than or equal to 1.5% and the accuracy was 104.0-105.0% and method was validated accordance with International Conference on Harmonization (ICH) guidelines to check content uniformity. In this lieu, a simple and rapid with good accuracy precision validated method is developed which is applicable in quality-estimation, in-future.