Calculation of the Short-time Withstand Current for Air Circuit Breaker

Honggang Xiang, Degui Chen, Xingwen Li, Liang Ji, W. Tong
{"title":"Calculation of the Short-time Withstand Current for Air Circuit Breaker","authors":"Honggang Xiang, Degui Chen, Xingwen Li, Liang Ji, W. Tong","doi":"10.1109/HOLM.2007.4318225","DOIUrl":null,"url":null,"abstract":"In the optimization design of contact system for the air circuit breaker (ACB), it is important to calculate the short-time withstand current. Introducing the contact bridges to describe contact spots between movable and fixed contacts, transient analysis is carried out by coupling electromagnetic field and thermal field to parallel contact systems, where nonlinear of ferromagnetic splitter plates and properties of conduct material varying with temperature are under consideration. In each time step of calculation, the cross-sectional areas of the contact bridges are changed with the contact forces by Holm formula. The proposed method could be used to analyze the short-time withstand current of ACB.","PeriodicalId":11624,"journal":{"name":"Electrical Contacts - 2007 Proceedings of the 53rd IEEE Holm Conference on Electrical Contacts","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Contacts - 2007 Proceedings of the 53rd IEEE Holm Conference on Electrical Contacts","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.2007.4318225","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

In the optimization design of contact system for the air circuit breaker (ACB), it is important to calculate the short-time withstand current. Introducing the contact bridges to describe contact spots between movable and fixed contacts, transient analysis is carried out by coupling electromagnetic field and thermal field to parallel contact systems, where nonlinear of ferromagnetic splitter plates and properties of conduct material varying with temperature are under consideration. In each time step of calculation, the cross-sectional areas of the contact bridges are changed with the contact forces by Holm formula. The proposed method could be used to analyze the short-time withstand current of ACB.
空气断路器短时耐压电流的计算
在空气断路器触点系统的优化设计中,短路耐受电流的计算是一个重要的问题。引入接触桥来描述动触点和固定触点之间的接触点,通过电磁场和热场的耦合对并联接触系统进行瞬态分析,考虑了铁磁分流板的非线性和导电材料随温度变化的特性。在计算的每个时间步长,接触桥的横截面积随接触力的变化采用Holm公式。该方法可用于ACB的短时耐压电流分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信