G. Wu, B. Brown, D. Capista, R. Flora, D.E. Johnson, K. Martin
{"title":"Tune control in the Fermilab Main Injector","authors":"G. Wu, B. Brown, D. Capista, R. Flora, D.E. Johnson, K. Martin","doi":"10.1109/PAC.1999.795331","DOIUrl":null,"url":null,"abstract":"We describe methods used to measure and control tunes in the Fermilab Main Injector (FMI). Emphasis is given to software implementation of the operator interface, to the front-end embedded computer system, and handling of hysteresis of main dipole and quadrupole magnets. Techniques are developed to permit control of tune of the Main Injector through several acceleration cycles: from 8.9 GeV/c to 120 GeV/c, from 8.9 GeV/c to 150 GeV/c, and from 150 GeV/c to 8.9 GeV/c. Systems which automate the complex interactions between tune measurement and the variety of ramping options are described. Some results of tune measurements and their comparison with the design model are presented.","PeriodicalId":20453,"journal":{"name":"Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAC.1999.795331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
We describe methods used to measure and control tunes in the Fermilab Main Injector (FMI). Emphasis is given to software implementation of the operator interface, to the front-end embedded computer system, and handling of hysteresis of main dipole and quadrupole magnets. Techniques are developed to permit control of tune of the Main Injector through several acceleration cycles: from 8.9 GeV/c to 120 GeV/c, from 8.9 GeV/c to 150 GeV/c, and from 150 GeV/c to 8.9 GeV/c. Systems which automate the complex interactions between tune measurement and the variety of ramping options are described. Some results of tune measurements and their comparison with the design model are presented.