The Effect of Temperature and Humidity on Audible Noise Generated from UHV DC Transmission Lines

Wei Wang, Bing An, Chengrong Li, B. Luo, Xiaolin Li, Yixu Wang, Fei Fan, Boo-gen Yang
{"title":"The Effect of Temperature and Humidity on Audible Noise Generated from UHV DC Transmission Lines","authors":"Wei Wang, Bing An, Chengrong Li, B. Luo, Xiaolin Li, Yixu Wang, Fei Fan, Boo-gen Yang","doi":"10.1109/CEIDP.2008.4772911","DOIUrl":null,"url":null,"abstract":"To research the effect of temperature and humidity on audible noise generated from UHV DC transmission lines, a mini corona cage has been constructed and put in a manual environment room, which temperature and humidity can be controlled. At the same time, an audible noise performance measuring system by using A/C weighted network audible noise meter and 8 kHz acoustic sensor have been set up too. The audible noise generated from a copper line have been measured in a mini corona cage not only at different humidity from 30% to 95% but also at different temperature from 0degC to 30degC. The relationship between audible noise level and temperature and humidity have been observed.","PeriodicalId":6381,"journal":{"name":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"1921 1","pages":"287-289"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2008.4772911","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

To research the effect of temperature and humidity on audible noise generated from UHV DC transmission lines, a mini corona cage has been constructed and put in a manual environment room, which temperature and humidity can be controlled. At the same time, an audible noise performance measuring system by using A/C weighted network audible noise meter and 8 kHz acoustic sensor have been set up too. The audible noise generated from a copper line have been measured in a mini corona cage not only at different humidity from 30% to 95% but also at different temperature from 0degC to 30degC. The relationship between audible noise level and temperature and humidity have been observed.
温度和湿度对特高压直流输电线路可听噪声的影响
为了研究温度和湿度对特高压直流输电线路可听噪声的影响,搭建了一个微型电晕笼,放置在一个温湿度可控的人工环境室内。同时,还建立了一套由空调加权网络声噪声计和8khz声传感器组成的声噪声性能测量系统。在微型电晕笼中测量了铜线在30% ~ 95%的不同湿度和0℃~ 30℃的不同温度下产生的可听噪声。已观察到可听噪声水平与温度和湿度之间的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信