Stability Indicating UV-Spectrophotometric Method Development and its Validation for the Determination of Imatinib Mesylate in Bulk and Formulation

R. Sri, Soundarya Soundarya, K. B. Sri, S. M
{"title":"Stability Indicating UV-Spectrophotometric Method Development and its Validation for the Determination of Imatinib Mesylate in Bulk and Formulation","authors":"R. Sri, Soundarya Soundarya, K. B. Sri, S. M","doi":"10.52711/2231-5675.2022.00015","DOIUrl":null,"url":null,"abstract":"A Simple and precise UV-spectroscopic method was developed for the determination of Imatinib Mesylate in its bulk and formulation. The developed method has been validated for various parameters like specificity, accuracy, linearity, robustness according to USP general chapter<1225> and ICH Q2R1 guidelines. Pure solution of Imatinib Mesylate was scanned in the whole range of UV region where it has shown the maximum absorbance at 258nm. The RSD values for method precision and intermediate precision were found to be well within the acceptance criteria and the series of dilutions were found to be linear (2-12ug/ml) where r2= 0.999 was the regression value. Limit of detection (0.2925μg/ml) and Limit of quantification (0.8977μg/ml) of IMT were established. Further, the drug has been subjected to various stress conditions, and percent degraded was reported. Drug solutions have shown stability on the benchtop for up to 8 hours and 72 hours when the solutions were refrigerated.","PeriodicalId":8547,"journal":{"name":"Asian Journal of Pharmaceutical Analysis","volume":"8 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Pharmaceutical Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52711/2231-5675.2022.00015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A Simple and precise UV-spectroscopic method was developed for the determination of Imatinib Mesylate in its bulk and formulation. The developed method has been validated for various parameters like specificity, accuracy, linearity, robustness according to USP general chapter<1225> and ICH Q2R1 guidelines. Pure solution of Imatinib Mesylate was scanned in the whole range of UV region where it has shown the maximum absorbance at 258nm. The RSD values for method precision and intermediate precision were found to be well within the acceptance criteria and the series of dilutions were found to be linear (2-12ug/ml) where r2= 0.999 was the regression value. Limit of detection (0.2925μg/ml) and Limit of quantification (0.8977μg/ml) of IMT were established. Further, the drug has been subjected to various stress conditions, and percent degraded was reported. Drug solutions have shown stability on the benchtop for up to 8 hours and 72 hours when the solutions were refrigerated.
稳定性指示紫外分光光度法测定甲磺酸伊马替尼原料药和制剂的方法建立及验证
建立了甲磺酸伊马替尼原料药和制剂中甲磺酸伊马替尼含量的紫外光谱测定方法。根据USP通章和ICH Q2R1指南,对所开发的方法进行了特异性、准确性、线性、稳健性等各种参数的验证。对甲磺酸伊马替尼纯溶液进行全紫外扫描,在258nm处吸光度最大。方法精密度和中间精密度的RSD值均在可接受标准范围内,稀释度系列呈线性(2 ~ 12ug/ml),回归值r2= 0.999。建立了IMT的检测限(0.2925μg/ml)和定量限(0.8977μg/ml)。此外,该药物已受到各种压力条件,和百分比降解的报道。药物溶液在实验台上的稳定性可达8小时,冷藏后可达72小时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信