Assessment of Time-dependent Temperature Behaviour in Immature Concrete Walls using Numerical Analysis

IF 0.4 Q4 ENGINEERING, MULTIDISCIPLINARY
H. P. Rathnayaka, D. Dasanayake, H. Yapa
{"title":"Assessment of Time-dependent Temperature Behaviour in Immature Concrete Walls using Numerical Analysis","authors":"H. P. Rathnayaka, D. Dasanayake, H. Yapa","doi":"10.4038/engineer.v55i1.7486","DOIUrl":null,"url":null,"abstract":"Hydration of cement is exothermic and the consequent temperature development leads to non-structural cracking in immature concrete. The maximum internal temperature drop (T1) is a governing parameter towards thermal cracking, and for structural deigns, T1 values recommended in the codes of practice are commonly used. Past investigations show that such recommendations could be too conservative. Amid the complexity of concrete thermal behaviour, one good prediction option is to use numerical methods. In this light, this study attempted to formulate recommendations for T1 via finite element (FE) analysis. First, a commercial FE software was validated for two distinct experimental results and, second, the FE application was used to predict the temperature in concrete walls. The variables were: wall thickness (300 1000 mm); cement composition (350 560 kg/m3); and plywood/steel formwork types. Semi-adiabatic experiments were conducted to obtain the rate of heat evolution in concrete. The numerical results showed that the predicted T1 values were considerably lower than those recommended in two currently practiced guidelines. The observed disparity was in the range of 22% 34%. It was also shown that T1 could be further reduced by about 15% and 23.5% through supplementing the mixes with fly ash by 20% and 35%, respectively.","PeriodicalId":42812,"journal":{"name":"Engineer-Journal of the Institution of Engineers Sri Lanka","volume":"28 1","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2022-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineer-Journal of the Institution of Engineers Sri Lanka","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4038/engineer.v55i1.7486","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Hydration of cement is exothermic and the consequent temperature development leads to non-structural cracking in immature concrete. The maximum internal temperature drop (T1) is a governing parameter towards thermal cracking, and for structural deigns, T1 values recommended in the codes of practice are commonly used. Past investigations show that such recommendations could be too conservative. Amid the complexity of concrete thermal behaviour, one good prediction option is to use numerical methods. In this light, this study attempted to formulate recommendations for T1 via finite element (FE) analysis. First, a commercial FE software was validated for two distinct experimental results and, second, the FE application was used to predict the temperature in concrete walls. The variables were: wall thickness (300 1000 mm); cement composition (350 560 kg/m3); and plywood/steel formwork types. Semi-adiabatic experiments were conducted to obtain the rate of heat evolution in concrete. The numerical results showed that the predicted T1 values were considerably lower than those recommended in two currently practiced guidelines. The observed disparity was in the range of 22% 34%. It was also shown that T1 could be further reduced by about 15% and 23.5% through supplementing the mixes with fly ash by 20% and 35%, respectively.
未成熟混凝土墙体温度随时间变化特性的数值分析
水泥的水化作用是放热的,随之而来的温度发展导致了未成熟混凝土的非结构性开裂。最大内部温度降(T1)是热裂的控制参数,对于结构设计,通常使用操作规范中推荐的T1值。过去的调查显示,这样的建议可能过于保守。考虑到混凝土热性能的复杂性,使用数值方法是一种很好的预测方法。鉴于此,本研究试图通过有限元(FE)分析制定T1的建议。首先,商业有限元软件验证了两个不同的实验结果,其次,有限元应用程序用于预测混凝土墙内的温度。变量为:壁厚(300 ~ 1000 mm);水泥成分(350 - 560 kg/m3);和胶合板/钢模板类型。进行了半绝热试验,得到了混凝土的放热速率。数值结果表明,预测的T1值大大低于目前两个实践指南的推荐值。观察到的差距在22% - 34%之间。粉煤灰掺量分别为20%和35%,可进一步降低T1约15%和23.5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
38
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信