{"title":"Assessment of the Correlation between Insertion Torque and Resonance Frequency Analysis of Implants placed in Bone Tissue of Different Densities.","authors":"Luiz Carlos Magno Filho, F. R. Cirano, F. Hayashi, F. Hsu, Conte Alexandre, L. Dib, M. Casati","doi":"10.1563/aaid-joi-d-11-00183.1","DOIUrl":null,"url":null,"abstract":"Abstract The primary stability of a dental implant is fundamental for the osseointegration. Therefore, the aim of this study was to assess the correlation between insertion torque (IT) and resonance frequency analysis (RFA) of implants placed in the mandible and maxilla of different bone densities. Eighty dental implants were placed in the maxilla and mandible and IT and the implant stability quotient (ISQ) were measured at the time of implant insertion. Bone density was assessed subjectively by the Lekholm and Zarb index (1985). The Type I and II densities were grouped together (Group A) and Type III and IV densities in another group (Group B). The IT in Group A was higher (student-t Test, p=0.0013) than IT in Group B (46.27 + 18.51 N/cm, 33.62 + 14.74 N/cm, respectively). The implants placed in Group A showed higher ISQ (student-t Test, p=0.0004) than those placed in Group B (70.09 + 7.50, 63.66 + 8.00, respectively). A significant correlation between IT and the ISQ value was observed for Group A (Pearson correlation test; r= 0.35; p= 0.0213) and for Group B (r= 0.37; p= 0.0224). Within the limitations of this study, it was possible to conclude that there is a correlation between IT and RFA of implants placed in the mandible and maxilla of different bone densities.","PeriodicalId":77634,"journal":{"name":"The International journal of oral implantology : implantologist","volume":"2 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of oral implantology : implantologist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-joi-d-11-00183.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract The primary stability of a dental implant is fundamental for the osseointegration. Therefore, the aim of this study was to assess the correlation between insertion torque (IT) and resonance frequency analysis (RFA) of implants placed in the mandible and maxilla of different bone densities. Eighty dental implants were placed in the maxilla and mandible and IT and the implant stability quotient (ISQ) were measured at the time of implant insertion. Bone density was assessed subjectively by the Lekholm and Zarb index (1985). The Type I and II densities were grouped together (Group A) and Type III and IV densities in another group (Group B). The IT in Group A was higher (student-t Test, p=0.0013) than IT in Group B (46.27 + 18.51 N/cm, 33.62 + 14.74 N/cm, respectively). The implants placed in Group A showed higher ISQ (student-t Test, p=0.0004) than those placed in Group B (70.09 + 7.50, 63.66 + 8.00, respectively). A significant correlation between IT and the ISQ value was observed for Group A (Pearson correlation test; r= 0.35; p= 0.0213) and for Group B (r= 0.37; p= 0.0224). Within the limitations of this study, it was possible to conclude that there is a correlation between IT and RFA of implants placed in the mandible and maxilla of different bone densities.
植入不同密度骨组织的植入扭矩与共振频率的相关性评估。
种植体的初级稳定性是种植体骨整合的基础。因此,本研究的目的是评估植入不同骨密度的下颌骨的植入扭矩(IT)和共振频率分析(RFA)之间的相关性。在上颌和下颌骨放置80颗种植体,在种植体插入时测量IT和种植体稳定商(ISQ)。骨密度主观评价采用Lekholm和Zarb指数(1985)。将ⅰ型和ⅱ型密度组合并(A组),另设ⅰ型和ⅳ型密度组(B组),A组的IT高于B组(分别为46.27 + 18.51 N/cm、33.62 + 14.74 N/cm)(学生t检验,p=0.0013)。A组的ISQ高于B组(70.09 + 7.50,63.66 + 8.00)(学生t检验,p=0.0004)。A组IT与ISQ值存在显著相关(Pearson相关检验;r = 0.35;p= 0.0213), B组(r= 0.37;p = 0.0224)。在本研究的局限性内,可以得出结论,在不同骨密度的下颌骨和上颌骨植入物的it和RFA之间存在相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书