MS/MS-libraries with triple quadrupole-tandem mass spectrometers for drug identification and drug screening

W. Weinmann, M. Gergov, M. Goerner
{"title":"MS/MS-libraries with triple quadrupole-tandem mass spectrometers for drug identification and drug screening","authors":"W. Weinmann, M. Gergov, M. Goerner","doi":"10.1051/ANALUSIS:2000280934","DOIUrl":null,"url":null,"abstract":"Two MS/MS libraries of drugs created by electroscopy ionisation (ESI) and collision-induced dissociation (CID) of the quasimolecular ions have been developed with triple-quadrupole ion-spray mass spectrometers. for both libraries three and four different collision energies were used, rezspectively, to ontain a variety of CID spectra, which were all included separately into the MS/MS librarie. The MS/MS product ion spectraof more than 400 drugs were acquired in positive or negative mode in two labrories independetly. recently, on of these MS/MS libraries was applied successfully for the identification of drug metabolites and the other has been used for qualitative analysis of drugs in urine samples with data dependent experiments (DDE). In this work, the reproducibility of CID spectra has been tested with three instruments (including two different instruments) in three laboratories. For comparision of CID-spectra, library searching with a combination of the two libraries was performed and fit values were compared. With regard to libary fit values CID-spectra were found to be highly reproducible between the instruments, when similar CID gas pressure and collision energy were applied. In addition, the long-time reproducibility of CIS over 30 months with the API 365 was demonstrated. Furthermore, comparisions of in-source CID and CID by MS/MS was given. It can be concluded, that both MS/MS libraries created with APIs 365 can be used with both types of triple-quadrupole instruments from Sciex (API 365 and 2000) for drug identification. Two applications of these MS/MS spectra libraries in combination with data dependent experiments are summarised.","PeriodicalId":8221,"journal":{"name":"Analusis","volume":"38 1","pages":"934-941"},"PeriodicalIF":0.0000,"publicationDate":"2000-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"44","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analusis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ANALUSIS:2000280934","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 44

Abstract

Two MS/MS libraries of drugs created by electroscopy ionisation (ESI) and collision-induced dissociation (CID) of the quasimolecular ions have been developed with triple-quadrupole ion-spray mass spectrometers. for both libraries three and four different collision energies were used, rezspectively, to ontain a variety of CID spectra, which were all included separately into the MS/MS librarie. The MS/MS product ion spectraof more than 400 drugs were acquired in positive or negative mode in two labrories independetly. recently, on of these MS/MS libraries was applied successfully for the identification of drug metabolites and the other has been used for qualitative analysis of drugs in urine samples with data dependent experiments (DDE). In this work, the reproducibility of CID spectra has been tested with three instruments (including two different instruments) in three laboratories. For comparision of CID-spectra, library searching with a combination of the two libraries was performed and fit values were compared. With regard to libary fit values CID-spectra were found to be highly reproducible between the instruments, when similar CID gas pressure and collision energy were applied. In addition, the long-time reproducibility of CIS over 30 months with the API 365 was demonstrated. Furthermore, comparisions of in-source CID and CID by MS/MS was given. It can be concluded, that both MS/MS libraries created with APIs 365 can be used with both types of triple-quadrupole instruments from Sciex (API 365 and 2000) for drug identification. Two applications of these MS/MS spectra libraries in combination with data dependent experiments are summarised.
MS/MS-文库与三重四极杆串联质谱用于药物鉴定和药物筛选
利用三-四极杆离子喷雾质谱仪建立了两个准分子离子的电子电离(ESI)和碰撞诱导解离(CID)建立的药物MS/MS文库。两个库分别使用3种和4种不同的碰撞能来包含各种CID谱,并分别纳入MS/MS库。在两个实验室分别以阳性或阴性模式获得了400多种药物的MS/MS产物离子谱。最近,其中一个MS/MS文库成功应用于药物代谢物的鉴定,另一个已用于数据依赖实验(data dependent experiments, DDE)对尿样中的药物进行定性分析。在本工作中,在三个实验室用三种仪器(包括两种不同的仪器)测试了CID光谱的再现性。为了比较cid光谱,将两个库组合进行库搜索,并比较拟合值。当使用相似的CID气体压力和碰撞能量时,两种仪器之间的CID光谱具有较高的重现性。此外,证明了API 365的CIS在30个月以上的长时间重复性。并用MS/MS法比较了内源CID和内源CID的差异。由此可见,用API 365创建的两种MS/MS文库均可用于Sciex的两种类型的三四极杆仪器(API 365和2000)进行药物鉴定。结合数据依赖实验,总结了这些MS/MS谱库的两种应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信