{"title":"Cost-effective flow injection analysis systems for acetic acid","authors":"Kate Grudpan, Piyanete Sritharathikhun, Jaroon Jakmunee","doi":"10.1002/1098-2728(2000)12:3<129::AID-LRA2>3.0.CO;2-P","DOIUrl":null,"url":null,"abstract":"<p>We propose cost-effective flow injection analysis systems for acetic acid. The flow systems can be assembled with different types of components, including a clinical saline bag and laboratory-made detectors, resulting in various degrees of automation, varying from very simple ones to fully computerized control. The flow injection titrations are based on neutralization and are monitored by either spectrophotometry or conductometry. The flow injection procedures can be performed under conditions at non-steady or steady states. The proposed procedures are demonstrated for the application of analysis of vinegar samples for acidity. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:129–132, 2000</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"12 3","pages":"129-132"},"PeriodicalIF":0.0000,"publicationDate":"2000-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1098-2728(2000)12:3<129::AID-LRA2>3.0.CO;2-P","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/1098-2728%282000%2912%3A3%3C129%3A%3AAID-LRA2%3E3.0.CO%3B2-P","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
We propose cost-effective flow injection analysis systems for acetic acid. The flow systems can be assembled with different types of components, including a clinical saline bag and laboratory-made detectors, resulting in various degrees of automation, varying from very simple ones to fully computerized control. The flow injection titrations are based on neutralization and are monitored by either spectrophotometry or conductometry. The flow injection procedures can be performed under conditions at non-steady or steady states. The proposed procedures are demonstrated for the application of analysis of vinegar samples for acidity. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:129–132, 2000
具有成本效益的醋酸流动注射分析系统
我们提出了具有成本效益的醋酸流动注射分析系统。流动系统可以用不同类型的组件组装,包括临床生理盐水袋和实验室自制的检测器,从而实现不同程度的自动化,从非常简单的自动化到完全的计算机控制。流动注射滴定以中和为基础,通过分光光度法或电导法进行监测。流动注射过程可以在非稳态或稳态条件下进行。并对所提出的方法在食醋样品酸度分析中的应用进行了论证。©2000 John Wiley &儿子,Inc。实验室机器人与自动化(12):129 - 132,2000
本文章由计算机程序翻译,如有差异,请以英文原文为准。