Chronic Electrical Stimulation of the Otolith Organ: Preliminary Results in Humans with Bilateral Vestibulopathy and Sensorineural Hearing Loss

Á. Ramos Macías, Á. Ramos de Miguel, Isaura Rodriguez Montesdeoca, Silvia Borkoski Barreiro, J. C. Falcón González
{"title":"Chronic Electrical Stimulation of the Otolith Organ: Preliminary Results in Humans with Bilateral Vestibulopathy and Sensorineural Hearing Loss","authors":"Á. Ramos Macías, Á. Ramos de Miguel, Isaura Rodriguez Montesdeoca, Silvia Borkoski Barreiro, J. C. Falcón González","doi":"10.1159/000503600","DOIUrl":null,"url":null,"abstract":"Introduction: Bilateral vestibulopathy is an important cause of imbalance that is misdiagnosed. The clinical management of patients with bilateral vestibular loss remains difficult as there is no clear evidence for an effective treatment. In this paper, we try to analyze the effect of chronic electrical stimulation and adaptation to electrical stimulation of the vestibular system in humans when stimulating the otolith organ with a constant pulse train to mitigate imbalance due to bilateral vestibular dysfunction (BVD). Methods: We included 2 patients in our study with BVD according to Criteria Consensus of the Classification Committee of the Bárány Society. Both cases were implanted by using a full-band straight electrode to stimulate the otoliths organs and simultaneously for the cochlear stimulation we use a perimodiolar electrode. Results: In both cases Vestibular and clinical test (video head impulse test, videonistagmography cervical vestibular evoked myogenic potentials, cVEMP and oVEMP), subjective visual vertical test, computerized dynamic posturography, dynamic gait index, Time UP and Go test and dizziness handicap index) were performed. Posture and gait metrics reveal important improvement if compare with preoperartive situation. Oscillopsia, unsteadiness, independence and quality of life improved to almost normal situation. Discussion/Conclusion: Prosthetic implantation of the otolith organ in humans is technically feasible. Electrical stimulation might have potential effects on balance and this is stable after 1 year follow-up. This research provides new possibilities for the development of vestibular implants to improve gravito-inertial acceleration sensation, in this case by the otoliths stimulation.","PeriodicalId":8624,"journal":{"name":"Audiology and Neurotology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology and Neurotology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000503600","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

Introduction: Bilateral vestibulopathy is an important cause of imbalance that is misdiagnosed. The clinical management of patients with bilateral vestibular loss remains difficult as there is no clear evidence for an effective treatment. In this paper, we try to analyze the effect of chronic electrical stimulation and adaptation to electrical stimulation of the vestibular system in humans when stimulating the otolith organ with a constant pulse train to mitigate imbalance due to bilateral vestibular dysfunction (BVD). Methods: We included 2 patients in our study with BVD according to Criteria Consensus of the Classification Committee of the Bárány Society. Both cases were implanted by using a full-band straight electrode to stimulate the otoliths organs and simultaneously for the cochlear stimulation we use a perimodiolar electrode. Results: In both cases Vestibular and clinical test (video head impulse test, videonistagmography cervical vestibular evoked myogenic potentials, cVEMP and oVEMP), subjective visual vertical test, computerized dynamic posturography, dynamic gait index, Time UP and Go test and dizziness handicap index) were performed. Posture and gait metrics reveal important improvement if compare with preoperartive situation. Oscillopsia, unsteadiness, independence and quality of life improved to almost normal situation. Discussion/Conclusion: Prosthetic implantation of the otolith organ in humans is technically feasible. Electrical stimulation might have potential effects on balance and this is stable after 1 year follow-up. This research provides new possibilities for the development of vestibular implants to improve gravito-inertial acceleration sensation, in this case by the otoliths stimulation.
耳石器官的慢性电刺激:双侧前庭病变和感觉神经性听力损失患者的初步结果
导读:双侧前庭病变是导致失衡的重要原因,常被误诊。由于没有明确的有效治疗证据,双侧前庭功能丧失患者的临床管理仍然很困难。在本文中,我们试图分析慢性电刺激和适应电刺激对人类前庭系统的影响,以恒定的脉冲序列刺激耳石器官,以减轻双侧前庭功能障碍(BVD)引起的不平衡。方法:根据Bárány学会分类委员会的标准共识,我们纳入了2例BVD患者。两例植入术均采用全带直电极刺激耳石器官,同时采用磨牙周围电极刺激耳蜗。结果:两例患者均进行了前庭和临床测试(视频头脉冲测试、视频颈前诱发肌电位、cVEMP和oVEMP)、主观视觉垂直测试、计算机动态体位摄影、动态步态指数、Time UP and Go测试和头晕障碍指数)。与术前相比,姿势和步态指标显示了重要的改善。示波器、不稳定、独立和生活质量改善到几乎正常的情况。讨论/结论:人工耳石植入术在技术上是可行的。电刺激可能对平衡有潜在的影响,经过1年的随访,这种影响是稳定的。这项研究为前庭植入物的发展提供了新的可能性,以改善重力惯性加速度感觉,在这种情况下,通过耳石刺激。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信