CBCT image noise reduction and enhancement using Bi-Histogram method with bent activation function

Anita Thakur, M. Malik, Nishtha Phutela, P. Khare, Prashant Mor
{"title":"CBCT image noise reduction and enhancement using Bi-Histogram method with bent activation function","authors":"Anita Thakur, M. Malik, Nishtha Phutela, P. Khare, Prashant Mor","doi":"10.1109/INCITE.2016.7857624","DOIUrl":null,"url":null,"abstract":"Dental, oral and maxillofacial region are very sensitive so low radiation imaging technique like Cone Beam Computed Tomography (CBCT) is useful for investigation of diseases. But due to low radiation, quality of images is not fine they have noise and low contrast in visual impression. So for dentistry diagnostic purpose it is important to pre-process the CBCT image. This paper focuses on improvement of contrast, brightness and noise reduction of dental CBCT images by using Bi Histogram Equalization technique with bent activation function and adaptive median filter for noise reduction. The output image has been analyzed and evaluated using peak value ratio in term of Signal versus Noise (PSNR) and matrix of Structure in term of Similarity Index (SSIM). From the experimental results, it has been found that the adaptive median and Bi histogram with bent activation function has a better noise and enhancement capability as compare to convectional histogram method.","PeriodicalId":59618,"journal":{"name":"下一代","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"下一代","FirstCategoryId":"1092","ListUrlMain":"https://doi.org/10.1109/INCITE.2016.7857624","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Dental, oral and maxillofacial region are very sensitive so low radiation imaging technique like Cone Beam Computed Tomography (CBCT) is useful for investigation of diseases. But due to low radiation, quality of images is not fine they have noise and low contrast in visual impression. So for dentistry diagnostic purpose it is important to pre-process the CBCT image. This paper focuses on improvement of contrast, brightness and noise reduction of dental CBCT images by using Bi Histogram Equalization technique with bent activation function and adaptive median filter for noise reduction. The output image has been analyzed and evaluated using peak value ratio in term of Signal versus Noise (PSNR) and matrix of Structure in term of Similarity Index (SSIM). From the experimental results, it has been found that the adaptive median and Bi histogram with bent activation function has a better noise and enhancement capability as compare to convectional histogram method.
基于弯曲激活函数的双直方图方法的CBCT图像降噪与增强
牙齿、口腔和颌面部是非常敏感的区域,因此圆锥束计算机断层扫描(CBCT)等低辐射成像技术对疾病的调查是有用的。但由于低辐射,图像质量不佳,视觉上存在噪声和对比度低的问题。因此,为了达到牙科诊断的目的,对CBCT图像进行预处理是非常重要的。采用弯曲激活函数的Bi直方图均衡化技术和自适应中值滤波降噪技术,对牙科CBCT图像的对比度、亮度和降噪效果进行了改进。利用信噪比(PSNR)的峰值比和相似度指数(SSIM)的结构矩阵对输出图像进行分析和评价。实验结果表明,与传统直方图方法相比,具有弯曲激活函数的自适应中值和Bi直方图具有更好的噪声和增强能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
6212
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信