{"title":"Thermal Effect Analysis of Hot flow Manifold Made for Industrial Automated Washing Machine","authors":"P. G. Ekade","doi":"10.9790/1684-140306106115","DOIUrl":null,"url":null,"abstract":"Automated Manifold acting in component processing machine is developed with thermal effect assessment. Manifold to perform transfer of fluid and air through optimized inlet piping with pneumatically sliding whole assembly. Vertical and horizontal mounting feasibility for this assembly gives perfect solution to make transfer of fluid in any position. Non reachable geometrical surfaces and complex shapes are to be covered for washing and drying which are already with bur, oil and dirt. This manifold is to be installed in SPM washing machine. Heated air and heated fluid intake gives perfect required supply through output temperature in medium to perform cycle operations in SPM. Considered output temp of medium is at least 45°C. Manifold sliding design parameters are developed with considering all engineering terms. Manifold with optimized thermal effective solution to achieve minimum 45 ° C. Flow Analysis is performed with Rate of heat transfer through this dedicated manifold and heat fluxes on manifold body is validated in this work.","PeriodicalId":14565,"journal":{"name":"IOSR Journal of Mechanical and Civil Engineering","volume":"42 1","pages":"106-115"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IOSR Journal of Mechanical and Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9790/1684-140306106115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Automated Manifold acting in component processing machine is developed with thermal effect assessment. Manifold to perform transfer of fluid and air through optimized inlet piping with pneumatically sliding whole assembly. Vertical and horizontal mounting feasibility for this assembly gives perfect solution to make transfer of fluid in any position. Non reachable geometrical surfaces and complex shapes are to be covered for washing and drying which are already with bur, oil and dirt. This manifold is to be installed in SPM washing machine. Heated air and heated fluid intake gives perfect required supply through output temperature in medium to perform cycle operations in SPM. Considered output temp of medium is at least 45°C. Manifold sliding design parameters are developed with considering all engineering terms. Manifold with optimized thermal effective solution to achieve minimum 45 ° C. Flow Analysis is performed with Rate of heat transfer through this dedicated manifold and heat fluxes on manifold body is validated in this work.