A highly sensitive glucose biosensor based on a microstrip ring resonator

U. Schwerthoeffer, R. Weigel, D. Kissinger
{"title":"A highly sensitive glucose biosensor based on a microstrip ring resonator","authors":"U. Schwerthoeffer, R. Weigel, D. Kissinger","doi":"10.1109/IMWS-BIO.2013.6756148","DOIUrl":null,"url":null,"abstract":"This paper presents a highly sensitive biosensor based on a microstrip ring resonator to detect glucose concentration. The proposed sensor structure allows observation of small variation of glucose concentration by two port S-parameter measurement. The sensor is based on a resonant microstrip ring with a microfluidic container placed on top. The interaction between the electric field and the milliliter range water-glucose solutions under test can be observed measuring the phase shift of the S-parameter from 3.98 to 4.05 GHz. Combining the microwave detection and the microfluidic network, a time efficient and low cost architecture is presented. With this technique a very sensitive water-glucose concentration of less than 50 mg/dl can be separated.","PeriodicalId":6321,"journal":{"name":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","volume":"1 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"33","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMWS-BIO.2013.6756148","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 33

Abstract

This paper presents a highly sensitive biosensor based on a microstrip ring resonator to detect glucose concentration. The proposed sensor structure allows observation of small variation of glucose concentration by two port S-parameter measurement. The sensor is based on a resonant microstrip ring with a microfluidic container placed on top. The interaction between the electric field and the milliliter range water-glucose solutions under test can be observed measuring the phase shift of the S-parameter from 3.98 to 4.05 GHz. Combining the microwave detection and the microfluidic network, a time efficient and low cost architecture is presented. With this technique a very sensitive water-glucose concentration of less than 50 mg/dl can be separated.
一种基于微带环形谐振器的高灵敏度葡萄糖生物传感器
本文提出了一种基于微带环形谐振器的高灵敏度生物传感器,用于检测葡萄糖浓度。所提出的传感器结构允许通过双端口s参数测量来观察葡萄糖浓度的微小变化。该传感器基于谐振微带环,顶部放置微流体容器。通过测量s参数在3.98 ~ 4.05 GHz范围内的相移,可以观察到电场与毫升范围内的水-葡萄糖溶液之间的相互作用。将微波检测与微流控网络相结合,提出了一种省时、低成本的微流控网络结构。用这种技术可以分离出非常敏感的水-葡萄糖浓度小于50mg /dl。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信