{"title":"Impact of WBG Converter Voltage Rise-Time and Switching Frequency on the PDIV of Twisted Pairs","authors":"A. Rumi, A. Cavallini, L. Lusuardi","doi":"10.1109/ICD46958.2020.9341897","DOIUrl":null,"url":null,"abstract":"The effect of wide bandgap converter on the partial discharge inception voltage (PDIV) of enameled magnet wires was investigated. Tests were carried out using an optical detection system, changing the rise time and the switching frequency. The experiments showed that neither the rise time nor the switching frequency influence the PDIV. Physically, this finding supports the idea that the permittivity does not change in the frequency range of the impulse voltage spectrum. However, the overshoot can affect PDIV measurements as neither the peak voltage nor the dc bus voltage provides an accurate evaluation of the PDIV.","PeriodicalId":6795,"journal":{"name":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","volume":"29 1","pages":"902-905"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICD46958.2020.9341897","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The effect of wide bandgap converter on the partial discharge inception voltage (PDIV) of enameled magnet wires was investigated. Tests were carried out using an optical detection system, changing the rise time and the switching frequency. The experiments showed that neither the rise time nor the switching frequency influence the PDIV. Physically, this finding supports the idea that the permittivity does not change in the frequency range of the impulse voltage spectrum. However, the overshoot can affect PDIV measurements as neither the peak voltage nor the dc bus voltage provides an accurate evaluation of the PDIV.
WBG变换器电压上升时间和开关频率对双绞线PDIV的影响
研究了宽禁带变换器对漆包线局部放电起始电压(PDIV)的影响。试验采用光学检测系统,改变上升时间和开关频率。实验表明,上升时间和开关频率对PDIV没有影响。从物理上讲,这一发现支持了介电常数在脉冲电压谱的频率范围内不改变的观点。然而,超调会影响PDIV测量,因为峰值电压和直流母线电压都不能提供PDIV的准确评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信