Characterization of absolute phase angle in wideband current shunts at Inmetro

Rodrigo Rodrigues Nascimento Zampilis, Marcus Vinícius Viegas Pinto, Leonardo Augusto Abreu De Souza, Gean Marcos Geronymo, Regis Pinheiro Landim
{"title":"Characterization of absolute phase angle in wideband current shunts at Inmetro","authors":"Rodrigo Rodrigues Nascimento Zampilis, Marcus Vinícius Viegas Pinto, Leonardo Augusto Abreu De Souza, Gean Marcos Geronymo, Regis Pinheiro Landim","doi":"10.1109/I2MTC50364.2021.9459819","DOIUrl":null,"url":null,"abstract":"This paper describes the initial stage of implementing an absolute phase measurement system for the current “cage” type shunts built at Inmetro. The phase characterization of the shunts includes phase difference measurements that allow the realization of the absolute phase using three geometrically equal shunts calibrated in DC resistance. The measurement results of three shunts are presented and analyzed in comparison with the values obtained through the lumped equivalent circuit model. The results demonstrate the high capacity of the method of determining the absolute phase of shunts that have small phase shift errors. This method allowed, for the first time, the absolute phase measurement of impedances (shunts) below 10 ohms at Inmetro. The lowest measurement error was 0.4 microradians with an expanded uncertainty of 1.4 microradians for the 10 A shunt at 54 Hz.","PeriodicalId":6772,"journal":{"name":"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","volume":"89 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2MTC50364.2021.9459819","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper describes the initial stage of implementing an absolute phase measurement system for the current “cage” type shunts built at Inmetro. The phase characterization of the shunts includes phase difference measurements that allow the realization of the absolute phase using three geometrically equal shunts calibrated in DC resistance. The measurement results of three shunts are presented and analyzed in comparison with the values obtained through the lumped equivalent circuit model. The results demonstrate the high capacity of the method of determining the absolute phase of shunts that have small phase shift errors. This method allowed, for the first time, the absolute phase measurement of impedances (shunts) below 10 ohms at Inmetro. The lowest measurement error was 0.4 microradians with an expanded uncertainty of 1.4 microradians for the 10 A shunt at 54 Hz.
Inmetro宽带电流分流器中绝对相位角的表征
本文介绍了为Inmetro公司现有的“保持架”型分流器实施绝对相位测量系统的初始阶段。分流器的相位特性包括相位差测量,该测量允许使用三个几何相等的分流器在直流电阻中校准来实现绝对相位。给出了三种分流器的测量结果,并与集总等效电路模型的测量结果进行了对比分析。结果表明,该方法在确定相移误差小的分流器的绝对相位时具有很高的容量。该方法首次允许在Inmetro对低于10欧姆的阻抗(分流)进行绝对相位测量。最低测量误差为0.4微度,扩展不确定度为1.4微度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信