{"title":"HPLC analysis of biomarkers of Toluene and Xylene in human urine samples","authors":"P. Maurya, A. Yadav, P. Maurya","doi":"10.3126/ijosh.v13i3.46615","DOIUrl":null,"url":null,"abstract":"Introduction: Urinary Hippuric acid (HA) and Methylhippuric acid (MHA) are considered reliable biomarkers for monitoring exposure to toluene and xylenes. A simple and robust HPLC method for simultaneous determination of HA and MHA in urine samples was developed and validated as per Internation Conference on Harmonization (ICH) Q2 guidelines.\nMethods: Mobile phase consisting of two solvents A & B, solvent A was 0.1% TFA in water, and solvent B was 0.1% TFA in acetonitrile. Separation was performed in gradient elution mode and the time program was as follows - Time (min)/%B: 0/20, 4/20, 11/80, 11.1/90, 16/90, 16.1/20, 25/20. The detection wavelength was 205 nm.\nResults: The limits of detection (LOD) and quantification (LOQ) of HA in urine were 0.3 and 1.0 mg/L, and for MHA were 0.25 mg/L and 1.0 mg/L respectively and the recovery for HA and MHA were 95% and 98.9% respectively. \nConclusion: The developed method was successfully applied for the analysis of urine samples.","PeriodicalId":34250,"journal":{"name":"International Journal of Occupational Safety and Health","volume":"18 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Occupational Safety and Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/ijosh.v13i3.46615","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Social Sciences","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Urinary Hippuric acid (HA) and Methylhippuric acid (MHA) are considered reliable biomarkers for monitoring exposure to toluene and xylenes. A simple and robust HPLC method for simultaneous determination of HA and MHA in urine samples was developed and validated as per Internation Conference on Harmonization (ICH) Q2 guidelines.
Methods: Mobile phase consisting of two solvents A & B, solvent A was 0.1% TFA in water, and solvent B was 0.1% TFA in acetonitrile. Separation was performed in gradient elution mode and the time program was as follows - Time (min)/%B: 0/20, 4/20, 11/80, 11.1/90, 16/90, 16.1/20, 25/20. The detection wavelength was 205 nm.
Results: The limits of detection (LOD) and quantification (LOQ) of HA in urine were 0.3 and 1.0 mg/L, and for MHA were 0.25 mg/L and 1.0 mg/L respectively and the recovery for HA and MHA were 95% and 98.9% respectively.
Conclusion: The developed method was successfully applied for the analysis of urine samples.