The use of superconducting bolometers for detecting nanosecond heat pulses

S. Edwards, H. B. Rani, J. Wigmore
{"title":"The use of superconducting bolometers for detecting nanosecond heat pulses","authors":"S. Edwards, H. B. Rani, J. Wigmore","doi":"10.1088/0022-3735/22/8/009","DOIUrl":null,"url":null,"abstract":"The authors discuss the use of superconducting edge bolometers for detecting heat pulses in the regime in which pulse lengths are shorter than the bolometer response time. An algorithm is described which enables deconvolution of the observed bolometer signal to give the incident phonon flux. Backscattering data taken on 2 mm sapphire crystals suggest that the method will also be successful in the study of much thinner samples, for example, the 0.5 mm thick wafers used in MBE technology.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"14 1","pages":"582-586"},"PeriodicalIF":0.0000,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physics E: Scientific Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0022-3735/22/8/009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

The authors discuss the use of superconducting edge bolometers for detecting heat pulses in the regime in which pulse lengths are shorter than the bolometer response time. An algorithm is described which enables deconvolution of the observed bolometer signal to give the incident phonon flux. Backscattering data taken on 2 mm sapphire crystals suggest that the method will also be successful in the study of much thinner samples, for example, the 0.5 mm thick wafers used in MBE technology.
利用超导热计探测纳秒热脉冲
作者讨论了在脉冲长度短于测热计响应时间的情况下,利用超导边缘测热计检测热脉冲。描述了一种算法,使观测到的测热计信号的反褶积得到入射声子通量。在2毫米蓝宝石晶体上采集的后向散射数据表明,该方法也将成功地用于研究更薄的样品,例如,在MBE技术中使用的0.5毫米厚的晶圆。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信