{"title":"\"A Survey of Diagnostic X-ray room design and shielding Integrity of Lead\nAprons in a State in North-Eastern Nigeria.\"","authors":"A. Mohammed, C. Nzotta, B. F. Nkubli, A. Umar, S. Y. Bappah, P. E. Osayaba, A. A. Dukku","doi":"10.48153/jrrs/2020/teza1728","DOIUrl":null,"url":null,"abstract":"Background: X-ray facility design and shielding integrity is meant to optimize radiation safety of patients, staff and the general public. \n\nObjectives: To determine the conformity to x-ray room design standards and the functional efficacy of lead aprons in the surveyed facilities.\n\nMaterials and Method: The survey was conducted in six radio diagnostic centres in Gombe State Nigeria, labelled A to F for anonymity. The building layout of the radiology departments was sketched to show the dimensions (L x B x H) and adjoining structures. Datasheets were also used to record information about the radio-diagnostic facility. Lead aprons were inspected for defects by physical observation and by x-ray exposure.\n\nResults: The x-ray room dimension of the six radio diagnostic centres with A (24 m2), B (14.8 m2), C (30 m2), D (36 m2), E (21.2 m2) and F (25 m2). All the walls of\n\nthe radio-diagnostic room of facility A, B, C and D were lined with 2 mm lead equivalent, whereas E and F were not. About 7 (38.8%) of lead aprons inspected were defective, while 11 (61.1%) were not defective.\n\nConclusion: There are compromises noted in the design of facility B and the majority of the lead aprons inspected showed good functional efficacy.","PeriodicalId":16919,"journal":{"name":"Journal of Radiography and Radiation Sciences","volume":"107 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiography and Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.48153/jrrs/2020/teza1728","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: X-ray facility design and shielding integrity is meant to optimize radiation safety of patients, staff and the general public.
Objectives: To determine the conformity to x-ray room design standards and the functional efficacy of lead aprons in the surveyed facilities.
Materials and Method: The survey was conducted in six radio diagnostic centres in Gombe State Nigeria, labelled A to F for anonymity. The building layout of the radiology departments was sketched to show the dimensions (L x B x H) and adjoining structures. Datasheets were also used to record information about the radio-diagnostic facility. Lead aprons were inspected for defects by physical observation and by x-ray exposure.
Results: The x-ray room dimension of the six radio diagnostic centres with A (24 m2), B (14.8 m2), C (30 m2), D (36 m2), E (21.2 m2) and F (25 m2). All the walls of
the radio-diagnostic room of facility A, B, C and D were lined with 2 mm lead equivalent, whereas E and F were not. About 7 (38.8%) of lead aprons inspected were defective, while 11 (61.1%) were not defective.
Conclusion: There are compromises noted in the design of facility B and the majority of the lead aprons inspected showed good functional efficacy.