[Study on the limitation for detecting anaerobic threshold by respiratory frequency].

T. Shimana, N. Kondo, S. Koga, T. Kashimoto, A. Iwata
{"title":"[Study on the limitation for detecting anaerobic threshold by respiratory frequency].","authors":"T. Shimana, N. Kondo, S. Koga, T. Kashimoto, A. Iwata","doi":"10.7600/JSPFSM1949.43.84","DOIUrl":null,"url":null,"abstract":"It has been reported that respiratory frequency (F) serves to determine anaerobic threshold (AT). The purpose of this study was to investigate whether the method detecting AT by using F is influenced by the subject's condition such as the existence of sport experiences. Ten healthy adults volunteered to perform progressive cycle ergometer exercise with workloads increased by 30-W (female:20-W) every 2 min at 60 rpm. VO2 at AT were determined by four different methods, which detect the point of 1)nonlinear increase in VE, VCO2, and increase in VE/VO2 without increasing in VE/VCO2 (AT-v), 2) nonlinear increase in F (visual estimation: AT-VF), 3) inflection in F by multisegment linear regression (AT-CF), 4) inflection with omitting above RC point as with 3) (AT-CF2). The mean VO2 at AT-VF (40.8 +/- 9.2 ml/kg/min) and AT-CF (42.7 +/- 9.9 ml/kg/min) was significantly higher compared with AT-V (28.2 +/- 10.4 ml/kg/min) and not RC (42.3 +/- 10.0 ml/kg/min). It would be possible that AT-VF and AT-CF indicated RC, but not AT. There were no significant differences between AT-CF2 (28.2 +/- 10.9 ml/kg/min) and AT-V, and a highly positive correlation (r = 0.79, p less than 0.05) was observed between them. It was recognized that F reached a plateau at AT in four of the subjects. The error between AT-V and AT-CF2 was observed individual variations and the error between them within 5% was observed in only one subject. These results suggest that F is inadequate as an indicator of the AT, because F may be influenced by entrainment of breathing and pedalling frequency.","PeriodicalId":77409,"journal":{"name":"The Annals of physiological anthropology = Seiri Jinruigaku Kenkyukai kaishi","volume":"16 1","pages":"237-42"},"PeriodicalIF":0.0000,"publicationDate":"1994-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Annals of physiological anthropology = Seiri Jinruigaku Kenkyukai kaishi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7600/JSPFSM1949.43.84","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

It has been reported that respiratory frequency (F) serves to determine anaerobic threshold (AT). The purpose of this study was to investigate whether the method detecting AT by using F is influenced by the subject's condition such as the existence of sport experiences. Ten healthy adults volunteered to perform progressive cycle ergometer exercise with workloads increased by 30-W (female:20-W) every 2 min at 60 rpm. VO2 at AT were determined by four different methods, which detect the point of 1)nonlinear increase in VE, VCO2, and increase in VE/VO2 without increasing in VE/VCO2 (AT-v), 2) nonlinear increase in F (visual estimation: AT-VF), 3) inflection in F by multisegment linear regression (AT-CF), 4) inflection with omitting above RC point as with 3) (AT-CF2). The mean VO2 at AT-VF (40.8 +/- 9.2 ml/kg/min) and AT-CF (42.7 +/- 9.9 ml/kg/min) was significantly higher compared with AT-V (28.2 +/- 10.4 ml/kg/min) and not RC (42.3 +/- 10.0 ml/kg/min). It would be possible that AT-VF and AT-CF indicated RC, but not AT. There were no significant differences between AT-CF2 (28.2 +/- 10.9 ml/kg/min) and AT-V, and a highly positive correlation (r = 0.79, p less than 0.05) was observed between them. It was recognized that F reached a plateau at AT in four of the subjects. The error between AT-V and AT-CF2 was observed individual variations and the error between them within 5% was observed in only one subject. These results suggest that F is inadequate as an indicator of the AT, because F may be influenced by entrainment of breathing and pedalling frequency.
用呼吸频率检测无氧阈值的局限性研究
据报道,呼吸频率(F)用于确定厌氧阈值(AT)。本研究的目的是探讨使用F检测AT的方法是否受到被试条件(如运动经验的存在)的影响。10名健康成人自愿进行渐进式循环力计运动,负荷每2分钟增加30瓦(女性:20瓦),转速为60转。采用四种不同的方法测定at处的VO2,分别检测1)VE、VCO2的非线性增加和VE/VO2的增加而VE/VCO2没有增加(at -v), 2) F的非线性增加(视觉估计:at - vf), 3)用多段线性回归(at - cf)检测F的拐点,4)与3)(at - cf2)一样忽略RC点以上的拐点。at - vf组(40.8 +/- 9.2 ml/kg/min)和at - cf组(42.7 +/- 9.9 ml/kg/min)的平均VO2明显高于at - v组(28.2 +/- 10.4 ml/kg/min),而RC组(42.3 +/- 10.0 ml/kg/min)。AT- vf和AT- cf可能提示RC,但不提示AT。AT-CF2 (28.2 +/- 10.9 ml/kg/min)与AT-V之间无显著差异,呈高度正相关(r = 0.79, p < 0.05)。人们认识到,在4个受试者中,F在at达到了平稳期。AT-V与AT-CF2的误差存在个体差异,误差在5%以内的只有一个被试。这些结果表明,F不足以作为AT的指标,因为F可能受到呼吸和蹬车频率的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书