Pengaruh Penempatan Lightning Arrester Sebelum Dan Sesudah Fuse Cut Out Terhadap Tegangan Lebih Pada Transformator Distribusi 20 Kv Di PT. PLN (Persero) Rayon Tanjung Karang

Dasweptia Dasweptia, A. Hamdani, Tommy Kurniawan
{"title":"Pengaruh Penempatan Lightning Arrester Sebelum Dan Sesudah Fuse Cut Out Terhadap Tegangan Lebih Pada Transformator Distribusi 20 Kv Di PT. PLN (Persero) Rayon Tanjung Karang","authors":"Dasweptia Dasweptia, A. Hamdani, Tommy Kurniawan","doi":"10.36269/jtr.v4i1.988","DOIUrl":null,"url":null,"abstract":"Lightning strikes on airborne transmission networks such as in distribution lines are injections of electric charge. The injection of the charge will cause a voltage increase in the network, so that more tension will arise in the network. Lightning Arrester (LA) is one of the equipment in the protection system to protect the 20 kV distribution transformer against overvoltage coming from lightning strikes. Under normal circumstances LA acts as an insulator, but when exposed to lightning strikes LA will function as a conductor whose resistance is relatively low, so that it can flow the surge current to the ground. This study aims to see the effect of the placement of lightning arresters before and after fuse cut out on overvoltage in the 20 KV distribution transformer, so that which placement is better is obtained, taking into account factors that affect the level of voltage and overcurrent that occurs in each system such as the location of LA placement, the steepness of incoming waves, the speed of propagation of surja waves, the voltage is large through the protection system, and the Basic Insulation Level (BIL) value of the equipment. So that in the end, the right PLACEMENT of LA was obtained as a 20 kv distribution transformer protection. Based on the results of the study, the voltage that reached the transformer was 67,192 kV, in this condition the transformer was still in a safe state because the voltage hitting the transformer was smaller than the transformer's BIL, which was 67.192kV<125 kV. the installation of the arrester after Fuse Cut Out is better because the voltage hitting the transformer is smaller than the installation of the arrester before Fuse Cut Out with a voltage difference of 69,092 kV - 67,192 kV = 1.9 kV.","PeriodicalId":31626,"journal":{"name":"Volt Jurnal Ilmiah Pendidikan Teknik Elektro","volume":"26 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volt Jurnal Ilmiah Pendidikan Teknik Elektro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36269/jtr.v4i1.988","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Lightning strikes on airborne transmission networks such as in distribution lines are injections of electric charge. The injection of the charge will cause a voltage increase in the network, so that more tension will arise in the network. Lightning Arrester (LA) is one of the equipment in the protection system to protect the 20 kV distribution transformer against overvoltage coming from lightning strikes. Under normal circumstances LA acts as an insulator, but when exposed to lightning strikes LA will function as a conductor whose resistance is relatively low, so that it can flow the surge current to the ground. This study aims to see the effect of the placement of lightning arresters before and after fuse cut out on overvoltage in the 20 KV distribution transformer, so that which placement is better is obtained, taking into account factors that affect the level of voltage and overcurrent that occurs in each system such as the location of LA placement, the steepness of incoming waves, the speed of propagation of surja waves, the voltage is large through the protection system, and the Basic Insulation Level (BIL) value of the equipment. So that in the end, the right PLACEMENT of LA was obtained as a 20 kv distribution transformer protection. Based on the results of the study, the voltage that reached the transformer was 67,192 kV, in this condition the transformer was still in a safe state because the voltage hitting the transformer was smaller than the transformer's BIL, which was 67.192kV<125 kV. the installation of the arrester after Fuse Cut Out is better because the voltage hitting the transformer is smaller than the installation of the arrester before Fuse Cut Out with a voltage difference of 69,092 kV - 67,192 kV = 1.9 kV.
雷击对空中输电网络(如配电线路)的作用是注入电荷。电荷的注入会使网络中的电压升高,从而使网络中产生更大的张力。避雷器是保护20kv配电变压器免受雷击过电压影响的保护装置之一。在正常情况下,LA充当绝缘体,但当受到雷击时,LA将作为导体,其电阻相对较低,因此它可以将浪涌电流输送到地面。本研究的目的是观察熔断器切断前后避雷器的放置对20kv配电变压器过电压的影响,从而得出哪一种放置方式更好,同时考虑到影响各系统电压和过流水平的因素,如避雷器放置的位置、来波的陡峭度、过电波的传播速度、通过保护系统的电压较大等。设备的基本绝缘等级(BIL)值。最终确定了20kv配电变压器保护的正确位置。根据研究结果,到达变压器的电压为67192 kV,在此情况下,由于到达变压器的电压小于变压器的BIL值67.192kV<125 kV,因此变压器仍处于安全状态。熔断后安装避雷器较好,因为碰到变压器的电压比熔断前安装避雷器要小,电压差为69,092 kV - 67192 kV = 1.9 kV。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信