Evaluation and implementation of the STA R Max® hemostaseology analyzer in the central laboratory of a major hospital

IF 0.1 Q4 OTORHINOLARYNGOLOGY
B. Hofmann, C. Schröder, Niels Geisler, G. Stamminger
{"title":"Evaluation and implementation of the STA R Max® hemostaseology analyzer in the central laboratory of a major hospital","authors":"B. Hofmann, C. Schröder, Niels Geisler, G. Stamminger","doi":"10.1515/labmed-2017-0056","DOIUrl":null,"url":null,"abstract":"Abstract Due to a change of provider at Zentrum für Diagnostik at Klinikum Chemnitz a comprehensive validation of the STA R Max® analyser from Stago was undertaken. Alongside intra-assay and inter-assay determinations, a broad range of comparative measurements using pooled patient plasma were also carried out against the previous routine method (BCS XP from Siemens). Results obtained from routine and emergency sample testing are presented in this publication. Good to very good results were observed which allowed for a swift switchover in systems. Furthermore, user friendliness, reagents, turnaround times (TAT) and general susceptibilities of the new system were evaluated. After various adaptations to the diagnostic process, the transition to routine operation successfully took place.","PeriodicalId":49926,"journal":{"name":"Laboratoriumsmedizin-Journal of Laboratory Medicine","volume":"21 1","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratoriumsmedizin-Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/labmed-2017-0056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Due to a change of provider at Zentrum für Diagnostik at Klinikum Chemnitz a comprehensive validation of the STA R Max® analyser from Stago was undertaken. Alongside intra-assay and inter-assay determinations, a broad range of comparative measurements using pooled patient plasma were also carried out against the previous routine method (BCS XP from Siemens). Results obtained from routine and emergency sample testing are presented in this publication. Good to very good results were observed which allowed for a swift switchover in systems. Furthermore, user friendliness, reagents, turnaround times (TAT) and general susceptibilities of the new system were evaluated. After various adaptations to the diagnostic process, the transition to routine operation successfully took place.
STA R Max®血液学分析仪在某大医院中心实验室的评估与实施
由于Klinikum Chemnitz的Zentrum fr diagnostics公司更换了供应商,对Stago的STA R Max®分析仪进行了全面验证。除了测定内测定和测定间测定外,还对以前的常规方法(西门子的BCS XP)进行了广泛的患者血浆比较测量。从常规和紧急样品测试中获得的结果在本出版物中提出。观察到良好到非常好的结果,这允许系统中的快速切换。此外,还对新系统的用户友好性、试剂、周转时间(TAT)和一般敏感性进行了评估。在对诊断过程进行各种调整后,成功地过渡到常规操作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
1
审稿时长
>12 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信