Fire Risk Rating Assessment for Wood Specimens Coated with Flame Retardant

Eui Jin, Yeong-Jin Chung
{"title":"Fire Risk Rating Assessment for Wood Specimens Coated with Flame Retardant","authors":"Eui Jin, Yeong-Jin Chung","doi":"10.33696/nanotechnol.4.041","DOIUrl":null,"url":null,"abstract":"Chung's equations-II, -III, and -IV were applied to evaluate the fire risk and fire risk ratings of flame retardants. As an example, a wood specimen coated with a flame retardant was selected and tested using a cone calorimeter according to the ISO 5660-1 standard. The external heat flux was fixed to 50 kW/m2. Fire performance index-III used three variables to evaluate the initial fire risk: the time to ignition, first peak heat release rate, and first peak smoke release rate. Fire growth index-III was calculated using the first peak heat release rate, peak smoke production rate, and time to reach the first peak smoke production rate. This index is a standardized fire hazard category with poly(methyl methacrylate) as the reference material. The fire risk rating index, fire risk index-IV, is expressed as the value obtained by dividing the fire growth index-III by fire performance index-III. In this study, the methodology for fire risk rating evaluation is discussed.","PeriodicalId":94095,"journal":{"name":"Journal of nanotechnology and nanomaterials","volume":"2016 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nanotechnology and nanomaterials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33696/nanotechnol.4.041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Chung's equations-II, -III, and -IV were applied to evaluate the fire risk and fire risk ratings of flame retardants. As an example, a wood specimen coated with a flame retardant was selected and tested using a cone calorimeter according to the ISO 5660-1 standard. The external heat flux was fixed to 50 kW/m2. Fire performance index-III used three variables to evaluate the initial fire risk: the time to ignition, first peak heat release rate, and first peak smoke release rate. Fire growth index-III was calculated using the first peak heat release rate, peak smoke production rate, and time to reach the first peak smoke production rate. This index is a standardized fire hazard category with poly(methyl methacrylate) as the reference material. The fire risk rating index, fire risk index-IV, is expressed as the value obtained by dividing the fire growth index-III by fire performance index-III. In this study, the methodology for fire risk rating evaluation is discussed.
涂有阻燃剂的木材试样的火灾风险等级评定
Chung的方程- ii, -III和-IV应用于评估阻燃剂的火灾风险和火灾风险等级。作为一个例子,选择涂有阻燃剂的木材样品,并根据ISO 5660-1标准使用锥形量热计进行测试。外部热流密度固定为50 kW/m2。火灾性能指标- iii采用着火时间、首峰放热率、首峰放烟率三个变量来评价初始火灾风险。火灾生长指数- iii采用第一峰值放热率、峰值产烟率和到达第一峰值产烟率的时间来计算。该指标是以聚甲基丙烯酸甲酯为参考物质的标准化火灾隐患分类。火灾风险等级指数,即火灾风险指数- iv,表示为火灾生长指数- iii除以火灾性能指数- iii所得的值。本文讨论了火灾风险等级评定的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信