Variable flow and optimization of chiller loading effect on energy saving for screw vapor compression-single effect absorption hybrid chiller plant in hospital mechanical room ‒ case study: Tehran heart hospital

IF 1.2 4区 工程技术 Q3 ENGINEERING, MECHANICAL
R. Boghosian, M. Mafi, M. H. Panjeshahi, A. Ataei
{"title":"Variable flow and optimization of chiller loading effect on energy saving for screw vapor compression-single effect absorption hybrid chiller plant in hospital mechanical room ‒ case study: Tehran heart hospital","authors":"R. Boghosian, M. Mafi, M. H. Panjeshahi, A. Ataei","doi":"10.1051/MECA/2021006","DOIUrl":null,"url":null,"abstract":"Chiller plants are the most energy consuming system during summer season in residential, commercial and hospital buildings. The highly variable cooling demand of the buildings connected to a hybrid chiller plant included absorption and vapor compression chillers to achieve higher energy efficiencies is one of the important issues. Cooling load sharing strategies and apply the variable water flow system in chiller plant have a significant impact on energy consumption and consequently with more productivity and environmentally protected. This paper examines the behavior and pattern of energy consumption in a hybrid chiller plant that includes a combination of two air-cooled screw vapor compression and three single effect absorption chillers. In order to properly understand the pattern of energy consumption, an existing mechanical room in a hospital in Tehran has been studied for five months, and its energy consumption has been compared with the optimized model. The results indicate that the sequence of the chiller function and the way in which they are placed in the circuit during a partial load, is in highest importance in view point of energy saving also by Applying of variable water flow system for optimized chiller loading the more energy saving is achieved for hybrid absorption and vapor compression chiller plant.","PeriodicalId":49018,"journal":{"name":"Mechanics & Industry","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mechanics & Industry","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1051/MECA/2021006","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 1

Abstract

Chiller plants are the most energy consuming system during summer season in residential, commercial and hospital buildings. The highly variable cooling demand of the buildings connected to a hybrid chiller plant included absorption and vapor compression chillers to achieve higher energy efficiencies is one of the important issues. Cooling load sharing strategies and apply the variable water flow system in chiller plant have a significant impact on energy consumption and consequently with more productivity and environmentally protected. This paper examines the behavior and pattern of energy consumption in a hybrid chiller plant that includes a combination of two air-cooled screw vapor compression and three single effect absorption chillers. In order to properly understand the pattern of energy consumption, an existing mechanical room in a hospital in Tehran has been studied for five months, and its energy consumption has been compared with the optimized model. The results indicate that the sequence of the chiller function and the way in which they are placed in the circuit during a partial load, is in highest importance in view point of energy saving also by Applying of variable water flow system for optimized chiller loading the more energy saving is achieved for hybrid absorption and vapor compression chiller plant.
医院机械室螺杆式蒸汽压缩-单效吸收式混合冷水机组变流量及机组负荷优化对节能的影响——以德黑兰心脏医院为例
冷冻机是住宅、商业和医院建筑夏季能耗最大的系统。连接到包括吸收式和蒸汽压缩式冷水机组在内的混合冷水机组的建筑物的高度变化的冷却需求是实现更高能源效率的重要问题之一。冷负荷分担策略和变水流量系统在冷水机组中的应用对能源消耗有显著的影响,从而提高了生产率和环境保护。本文研究了一个由两台气冷螺杆蒸汽压缩机组和三台单效吸收式机组组成的混合式冷水机组的能耗行为和模式。为了正确理解能耗模式,对德黑兰某医院现有机械房进行了为期5个月的研究,并将其能耗与优化模型进行了比较。结果表明,从节能的角度来看,部分负荷时冷水机组的功能顺序及其在回路中的位置是最重要的,采用变水流量系统优化冷水机组负荷,对吸收式和蒸汽压缩式混合冷水机组节能效果更好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Mechanics & Industry
Mechanics & Industry ENGINEERING, MECHANICAL-MECHANICS
CiteScore
2.80
自引率
0.00%
发文量
25
审稿时长
>12 weeks
期刊介绍: An International Journal on Mechanical Sciences and Engineering Applications With papers from industry, Research and Development departments and academic institutions, this journal acts as an interface between research and industry, coordinating and disseminating scientific and technical mechanical research in relation to industrial activities. Targeted readers are technicians, engineers, executives, researchers, and teachers who are working in industrial companies as managers or in Research and Development departments, technical centres, laboratories, universities, technical and engineering schools. The journal is an AFM (Association Française de Mécanique) publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信