Hydrothorax caused by catheter malposition misdiagnosed via using plain radiography

A. Ergul, Alper Ozcan, Y. Torun
{"title":"Hydrothorax caused by catheter malposition misdiagnosed via using plain radiography","authors":"A. Ergul, Alper Ozcan, Y. Torun","doi":"10.5455/JTOMC.2017.03.036","DOIUrl":null,"url":null,"abstract":"We report the case of a child with hydrothorax caused by the misidentification of catheter malposition using plain radiography. A 9-month-old girl underwent central venous catheterization via the right subclavian vein. Catheter tip was evaluated mistakenly as in the right atrium by plain radiography. The catheter was retracted 2 cm and 1/3 normal saline infusion was initiated at 15 ml/hr. The patient became hypoxemic at the 20th hour of fluid infusion. On radiography, the right lung was completely opaque and the catheter tip was positioned in the right lung. Bedside sonography revealed a massive pleural effusion in the right lung and the catheter tip in the right pleural space. The catheter was removed and the pleural effusion was drained via chest tube. The location of the catheter tip should be determined by an accurate technique before infusing fluid. Plain radiography can be misleading for the detection of malposition.","PeriodicalId":17427,"journal":{"name":"Journal of Turgut Ozal Medical Center","volume":"21 1","pages":"1"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Turgut Ozal Medical Center","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5455/JTOMC.2017.03.036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

We report the case of a child with hydrothorax caused by the misidentification of catheter malposition using plain radiography. A 9-month-old girl underwent central venous catheterization via the right subclavian vein. Catheter tip was evaluated mistakenly as in the right atrium by plain radiography. The catheter was retracted 2 cm and 1/3 normal saline infusion was initiated at 15 ml/hr. The patient became hypoxemic at the 20th hour of fluid infusion. On radiography, the right lung was completely opaque and the catheter tip was positioned in the right lung. Bedside sonography revealed a massive pleural effusion in the right lung and the catheter tip in the right pleural space. The catheter was removed and the pleural effusion was drained via chest tube. The location of the catheter tip should be determined by an accurate technique before infusing fluid. Plain radiography can be misleading for the detection of malposition.
导管错位所致胸腔积液经x线平片误诊
我们报告的情况下,儿童与水胸引起的错误识别导管错位使用平片。一个9个月大的女孩通过右锁骨下静脉中心静脉导管。平片误以为导管尖端位于右心房。导管回撤2cm,以15ml /hr的速度开始1/3生理盐水输注。患者在输液第20小时出现低氧血症。x线片显示右肺完全不透明,导管尖端位于右肺内。床边超声检查显示右肺大量胸腔积液,导管尖端位于右侧胸腔间隙。取下导管,通过胸管排出胸腔积液。在输注液体之前,应该用精确的技术确定导管尖端的位置。x线平片可能会误导对错位的检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信