Methods of improving the pulse repetition frequency of high pressure gas switches

S. Macgregor, S. Turnbull, F. A. Tuema, A. Phelps
{"title":"Methods of improving the pulse repetition frequency of high pressure gas switches","authors":"S. Macgregor, S. Turnbull, F. A. Tuema, A. Phelps","doi":"10.1109/PPC.1995.596488","DOIUrl":null,"url":null,"abstract":"This paper describes several methods which have been developed to improve the pulse repetition frequency (PRF) of high pressure spark gap switches. Under pulse charged conditions, the voltage recovery process of the spark gap has been shown to be restricted by the residual ion population. This may be minimised by applying a suitable bias voltage across the gap. It is also possible to manipulate the V-p characteristic of a spark gap to improve the rate of rise of recovery voltage by reducing the recovery voltage dependence upon pressure. The combination of these effects has been shown to reduce the voltage recovery time of pulsed charged spark gaps from several hundred ms to several ms. Under DC conditions, it is possible to employ a corona discharge, found in a highly nonuniform field, to stabilise and control the voltage breakdown process. The use of corona stabilisation has enabled the operation of a spark gap at a PRF of more than 5 kHz, without employing gas flow techniques.","PeriodicalId":11163,"journal":{"name":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1995-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1995.596488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

This paper describes several methods which have been developed to improve the pulse repetition frequency (PRF) of high pressure spark gap switches. Under pulse charged conditions, the voltage recovery process of the spark gap has been shown to be restricted by the residual ion population. This may be minimised by applying a suitable bias voltage across the gap. It is also possible to manipulate the V-p characteristic of a spark gap to improve the rate of rise of recovery voltage by reducing the recovery voltage dependence upon pressure. The combination of these effects has been shown to reduce the voltage recovery time of pulsed charged spark gaps from several hundred ms to several ms. Under DC conditions, it is possible to employ a corona discharge, found in a highly nonuniform field, to stabilise and control the voltage breakdown process. The use of corona stabilisation has enabled the operation of a spark gap at a PRF of more than 5 kHz, without employing gas flow techniques.
提高高压气体开关脉冲重复频率的方法
本文介绍了提高高压火花隙开关脉冲重复频率的几种方法。在脉冲充电条件下,火花间隙的电压恢复过程受到残余离子数量的限制。这可以通过在间隙上施加合适的偏置电压来最小化。还可以通过控制火花间隙的V-p特性来降低恢复电压对压力的依赖,从而提高恢复电压的上升速率。这些效应的结合已被证明可以将脉冲充电火花间隙的电压恢复时间从几百毫秒减少到几毫秒。在直流条件下,可以使用在高度不均匀场中发现的电晕放电来稳定和控制电压击穿过程。使用电晕稳定技术,无需使用气体流动技术,就可以在PRF超过5 kHz的情况下操作火花间隙。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信