{"title":"Hydraulics of Stacked Drop Manholes","authors":"G. A. Camino, David Z. Zhu, N. Rajaratnam","doi":"10.1061/(ASCE)IR.1943-4774.0000327","DOIUrl":null,"url":null,"abstract":"This paper presents the results of an experimental investigation on flows inside stacked drop manholes (SDM). An SDM consists of two identical rectangular or square manhole chambers stacked together at an elevation difference. SDMs for different conditions were assessed on their ability to dissipate the energy of the approaching flow and their suitability to perform adequately under different flow conditions. Flow regimes were classified based on the inflow conditions and geometry of the structure in the first chamber and downstream outflows in the second chamber. An analysis based on the integral momentum equation was developed to estimate pool depths and energy losses under critical flow conditions. A fully surcharged stage with inflow and outflow pipes running full was also tested and velocity profiles were measured at a horizontal center plane to the opening connecting both shafts. Additionally, air flow rates were measured to assess the air demand into a large-height SDM.","PeriodicalId":16260,"journal":{"name":"Journal of Irrigation and Drainage Engineering-asce","volume":"40 1","pages":"537-552"},"PeriodicalIF":0.0000,"publicationDate":"2011-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Irrigation and Drainage Engineering-asce","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1061/(ASCE)IR.1943-4774.0000327","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15
Abstract
This paper presents the results of an experimental investigation on flows inside stacked drop manholes (SDM). An SDM consists of two identical rectangular or square manhole chambers stacked together at an elevation difference. SDMs for different conditions were assessed on their ability to dissipate the energy of the approaching flow and their suitability to perform adequately under different flow conditions. Flow regimes were classified based on the inflow conditions and geometry of the structure in the first chamber and downstream outflows in the second chamber. An analysis based on the integral momentum equation was developed to estimate pool depths and energy losses under critical flow conditions. A fully surcharged stage with inflow and outflow pipes running full was also tested and velocity profiles were measured at a horizontal center plane to the opening connecting both shafts. Additionally, air flow rates were measured to assess the air demand into a large-height SDM.