Long-term performance of the first grid-connected, building-integrated amorphous silicon PV installation in Brazil

R. Ruther, L. Nascimento, J. Urbanetz Junior, P. Pfitscher, T. Viana
{"title":"Long-term performance of the first grid-connected, building-integrated amorphous silicon PV installation in Brazil","authors":"R. Ruther, L. Nascimento, J. Urbanetz Junior, P. Pfitscher, T. Viana","doi":"10.1109/PVSC.2010.5617021","DOIUrl":null,"url":null,"abstract":"In this paper we present the performance assessment of the first grid-connected, building-integrated, thin-film PV system installed in Brazil in 1997. In the 12-years period since start up, the 40m2, 2kWp double-junction amorphous silicon BIPV generator operated continuously, with minimum downtime and high performance ratios. We also discuss reliability issues related to system design and inverter performance and replacement for the continuous operation of this distributed energy source in the urban environment of a warm-climate metropolitan state capital in Brazil.","PeriodicalId":6424,"journal":{"name":"2010 35th IEEE Photovoltaic Specialists Conference","volume":"154 1","pages":"002283-002286"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 35th IEEE Photovoltaic Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PVSC.2010.5617021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

In this paper we present the performance assessment of the first grid-connected, building-integrated, thin-film PV system installed in Brazil in 1997. In the 12-years period since start up, the 40m2, 2kWp double-junction amorphous silicon BIPV generator operated continuously, with minimum downtime and high performance ratios. We also discuss reliability issues related to system design and inverter performance and replacement for the continuous operation of this distributed energy source in the urban environment of a warm-climate metropolitan state capital in Brazil.
巴西首个并网、建筑一体化非晶硅光伏装置的长期性能
在本文中,我们介绍了1997年在巴西安装的第一个并网、建筑集成的薄膜光伏系统的性能评估。自启动以来的12年中,40m2, 2kWp双结非晶硅BIPV发电机连续运行,停机时间最短,性能比高。我们还讨论了与系统设计和逆变器性能相关的可靠性问题,以及在巴西一个气候温暖的大都市州首府的城市环境中,这种分布式能源的连续运行的更换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信