Endodontic techniques with Nickel Titanium instruments: analysis of quality and efficiency of instrumentation in primary molars

M. L. M. F. Fernandes, C. A. Maia, Gabriele Andrade Maia, Alice Machado Carvalho Santos, S. Paiva, A. M. Fernandes
{"title":"Endodontic techniques with Nickel Titanium instruments: analysis of quality and efficiency of instrumentation in primary molars","authors":"M. L. M. F. Fernandes, C. A. Maia, Gabriele Andrade Maia, Alice Machado Carvalho Santos, S. Paiva, A. M. Fernandes","doi":"10.1590/1981-86372023001620220005","DOIUrl":null,"url":null,"abstract":"ABSTRACT Objective: The purpose of the present in vitro study was to evaluate the efficiency of three different instruments in the root canals of artificial primary molars as well as the quality of the fillings. Methods: Sixty artificial primary molars were divided into three groups of 20 teeth. Each group was submitted to a different technique: Group 1 - conventional manual technique using Kerr files; Group 2 - manual technique with nickel-titanium files; Group 3 - NiTi rotary technique. The root canals were filled with calcium hydroxide paste. Aspects such as homogeneity of the fillings, taper and flowability of the preparations were considered comparatively to assess the quality of the instrumentations. The non-parametric Kruskal-Wallis and Mann-Whitney tests were used to compare the efficiency of the preparation of the root canal considering the preparation times of them. Results: All three techniques were equally effective at shaping the root canals of primary teeth. The working time was shorter with the rotary instrument (p=0.000). In the pairwise comparisons, working time was shorter with the rotary instrument compared to the manual techniques with steel files (p=0.000) and NiTi files (p=0.000). Comparing the manual techniques, the working time was shorter with NiTi files compared to steel files (p=0.011). Moreover, less variability in the preparation time was found when the rotary instrument was used. Conclusions: The mechanized rotary method led to a shorter operating time in comparison to the manual techniques and is therefore a preferable option for the preparation of the root canals of primary teeth.","PeriodicalId":30069,"journal":{"name":"RGO Revista Gaucha de Odontologia","volume":"124 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RGO Revista Gaucha de Odontologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/1981-86372023001620220005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

ABSTRACT Objective: The purpose of the present in vitro study was to evaluate the efficiency of three different instruments in the root canals of artificial primary molars as well as the quality of the fillings. Methods: Sixty artificial primary molars were divided into three groups of 20 teeth. Each group was submitted to a different technique: Group 1 - conventional manual technique using Kerr files; Group 2 - manual technique with nickel-titanium files; Group 3 - NiTi rotary technique. The root canals were filled with calcium hydroxide paste. Aspects such as homogeneity of the fillings, taper and flowability of the preparations were considered comparatively to assess the quality of the instrumentations. The non-parametric Kruskal-Wallis and Mann-Whitney tests were used to compare the efficiency of the preparation of the root canal considering the preparation times of them. Results: All three techniques were equally effective at shaping the root canals of primary teeth. The working time was shorter with the rotary instrument (p=0.000). In the pairwise comparisons, working time was shorter with the rotary instrument compared to the manual techniques with steel files (p=0.000) and NiTi files (p=0.000). Comparing the manual techniques, the working time was shorter with NiTi files compared to steel files (p=0.011). Moreover, less variability in the preparation time was found when the rotary instrument was used. Conclusions: The mechanized rotary method led to a shorter operating time in comparison to the manual techniques and is therefore a preferable option for the preparation of the root canals of primary teeth.
镍钛器械根管技术:第一磨牙器械质量与效率分析
摘要目的:评价三种不同器械在人工第一磨牙根管内的充填效果及充填物的质量。方法:60颗人工乳牙分为3组,每组20颗。每组采用不同的技术:第一组使用Kerr文件进行常规手工技术;第二组:手工镍钛锉工艺;第3组-镍钛旋转技术。根管内填充氢氧化钙糊剂。比较考虑了填料的均匀性、锥度和制剂的流动性等方面来评估仪器的质量。采用非参数Kruskal-Wallis检验和Mann-Whitney检验来比较考虑根管预备次数的根管预备效率。结果:三种方法对乳牙根管成形效果相同。旋转仪器的工作时间更短(p=0.000)。两两比较,旋转仪器的工作时间比手工钢锉(p=0.000)和镍钛锉(p=0.000)的工作时间短。与手工工艺相比,镍钛锉的工作时间比钢锉短(p=0.011)。此外,当使用旋转仪器时,制备时间的变化较小。结论:机械旋转法比手工方法操作时间短,是一种较好的预备乳牙根管的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
35
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信