Implementation of Quality by Design Approach for Optimization of RP-HPLC Method for Quantification of Abiraterone Acetate in Solid Dispersion in Forced Degradation Studies

S. Dubey, Manisha Choudhari, Mahipal Reddy Donthi, S. Damle, Gautam Singhvi, R. Saha
{"title":"Implementation of Quality by Design Approach for Optimization of RP-HPLC Method for Quantification of Abiraterone Acetate in Solid Dispersion in Forced Degradation Studies","authors":"S. Dubey, Manisha Choudhari, Mahipal Reddy Donthi, S. Damle, Gautam Singhvi, R. Saha","doi":"10.2174/2213240609666221110090339","DOIUrl":null,"url":null,"abstract":"\n\nAbiraterone acetate is a derivative of steroidal progesterone, used as a first-line therapy for metastatic castration of prostate cancer.\n\n\n\nThe present study encompasses the design of an experiment approach for developing a simple, reliable, and rapid RP-HPLC method for the estimation of abiraterone acetate.\n\n\n\nThe chromatographic separation was efficiently conducted on a Hypersil Gold C18 (50 x 4.6 mm, 5 µm) HPLC column, using the mobile phase composition of acetonitrile: dibasic potassium phosphate (0.01 mM) in the ratio of 80:20 (%v/v) at pH 6.5 with an isocratic elution mode. Furthermore, the different force degradation study including hydrolysis, oxidation, thermal, and photolytic was performed for abiraterone acetate.\n\n\n\nThe dynamic linearity was established in the concentration range of 0.5-10 µg/mL with r2 of 0.9998. Furthermore, the limit of detection and the limit of quantitation were 0.0978 µg/mL and 0.3260 µg/mL. The degradation of abiraterone acetate was shown in both acidic (54.16 ± 0.247 after 24 hrs) and basic conditions (35.06 ± 0.458 after 24 hrs). Furthermore, the developed method was successfully employed to quantify abiraterone acetate in bulk powder and the solid dispersion did not show any change in the retention time.\n\n\n\nThe developed method was validated according to the ICH Q2 (R1) specification, which was found to be sensitive, accurate, precise, robust, linear, and selective compared to the reported chromatographic method.\n","PeriodicalId":10826,"journal":{"name":"Current chromatography","volume":"89 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/2213240609666221110090339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Abiraterone acetate is a derivative of steroidal progesterone, used as a first-line therapy for metastatic castration of prostate cancer. The present study encompasses the design of an experiment approach for developing a simple, reliable, and rapid RP-HPLC method for the estimation of abiraterone acetate. The chromatographic separation was efficiently conducted on a Hypersil Gold C18 (50 x 4.6 mm, 5 µm) HPLC column, using the mobile phase composition of acetonitrile: dibasic potassium phosphate (0.01 mM) in the ratio of 80:20 (%v/v) at pH 6.5 with an isocratic elution mode. Furthermore, the different force degradation study including hydrolysis, oxidation, thermal, and photolytic was performed for abiraterone acetate. The dynamic linearity was established in the concentration range of 0.5-10 µg/mL with r2 of 0.9998. Furthermore, the limit of detection and the limit of quantitation were 0.0978 µg/mL and 0.3260 µg/mL. The degradation of abiraterone acetate was shown in both acidic (54.16 ± 0.247 after 24 hrs) and basic conditions (35.06 ± 0.458 after 24 hrs). Furthermore, the developed method was successfully employed to quantify abiraterone acetate in bulk powder and the solid dispersion did not show any change in the retention time. The developed method was validated according to the ICH Q2 (R1) specification, which was found to be sensitive, accurate, precise, robust, linear, and selective compared to the reported chromatographic method.
采用质量设计法优化RP-HPLC法定量醋酸阿比特龙固体分散体中强制降解研究
醋酸阿比特龙是甾体孕酮的衍生物,用于前列腺癌转移性去势的一线治疗。本研究旨在建立一种简单、可靠、快速的反相高效液相色谱法来测定醋酸阿比特龙的含量。采用Hypersil Gold C18 (50 × 4.6 mm, 5µm)高效液相色谱柱,流动相为乙腈:磷酸二钾(0.01 mm),比例为80:20 (%v/v), pH为6.5,等容洗脱。此外,还对醋酸阿比特龙进行了水解、氧化、热和光解等不同力的降解研究。在0.5 ~ 10µg/mL范围内呈线性关系,r2 = 0.9998。检测限和定量限分别为0.0978µg/mL和0.3260µg/mL。醋酸阿比特龙在酸性条件下(24 h后为54.16±0.247)和碱性条件下(24 h后为35.06±0.458)均有降解。此外,所建立的方法成功地用于定量散装粉末中的醋酸阿比特龙,固体分散体的保留时间没有任何变化。根据ICH Q2 (R1)规范对所开发的方法进行了验证,与报道的色谱方法相比,该方法具有灵敏度、准确性、精密度、鲁棒性、线性性和选择性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信