João Felipe Besegato, G. Rocha, M. Amorim, F. Salomão, D. Poletto, Kelly Limi Aida, P. Caldarelli, Márcio Grama Hoeppner
{"title":"Aferição do pH de diferentes agentes clareadores indicados para o clareamento intracoronário","authors":"João Felipe Besegato, G. Rocha, M. Amorim, F. Salomão, D. Poletto, Kelly Limi Aida, P. Caldarelli, Márcio Grama Hoeppner","doi":"10.11606/ISSN.2357-8041.CLRD.2018.143185","DOIUrl":null,"url":null,"abstract":"Objective : to measure pH values of bleaching agents that are indicated to intracoronal bleaching technique in different time intervals. Methods : Each group (G) received five samples (n=5): G1 – distilled water (AD); G2 – hydrogen peroxide (H2O2) 30%; G3 – sodium perborate (PbS) + AD; G4 – PbS + H2O2 30%; G5 – sodium percarbonate (PcS) + AD; and G6 – PcS + H2O2 30%. pH values were stated using a digital pHmeter, in different time intervals: immediately after handling (T0), 24 hours (T1) and 168 hours after handling (T2). The results were submitted to statistical analysis through Kruskal-Wallis and Mann Whitney tests, in this order, allowing multiple comparisons among the groups. To verify the effect of time in each group, Friedman test was applied. Results : In the evaluation of the effect of time in each group, it was observed that G2 presented acid behavior, while the other groups exhibited values close to neutrality or alkaline. Conclusions : H2O2 30% was the only agent that showed acidic behavior in every evaluation time. Meanwhile, PcS + H2O had the highest pH values.","PeriodicalId":10204,"journal":{"name":"Clinical and Laboratorial Research in Dentistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Laboratorial Research in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11606/ISSN.2357-8041.CLRD.2018.143185","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Objective : to measure pH values of bleaching agents that are indicated to intracoronal bleaching technique in different time intervals. Methods : Each group (G) received five samples (n=5): G1 – distilled water (AD); G2 – hydrogen peroxide (H2O2) 30%; G3 – sodium perborate (PbS) + AD; G4 – PbS + H2O2 30%; G5 – sodium percarbonate (PcS) + AD; and G6 – PcS + H2O2 30%. pH values were stated using a digital pHmeter, in different time intervals: immediately after handling (T0), 24 hours (T1) and 168 hours after handling (T2). The results were submitted to statistical analysis through Kruskal-Wallis and Mann Whitney tests, in this order, allowing multiple comparisons among the groups. To verify the effect of time in each group, Friedman test was applied. Results : In the evaluation of the effect of time in each group, it was observed that G2 presented acid behavior, while the other groups exhibited values close to neutrality or alkaline. Conclusions : H2O2 30% was the only agent that showed acidic behavior in every evaluation time. Meanwhile, PcS + H2O had the highest pH values.