High performance cardiac SPECT camera: Resolution and sensitivity simulations

J. Dey
{"title":"High performance cardiac SPECT camera: Resolution and sensitivity simulations","authors":"J. Dey","doi":"10.1109/NSSMIC.2010.5874299","DOIUrl":null,"url":null,"abstract":"SPECT is primarily used in the clinic for cardiac myocardial perfusion imaging (MPI). However, for SPECT, sensitivity is impaired due to the need for collimation. System resolution is poor as well. In this work we demonstrate the advantages of curved detector over a flat detector on a pinhole for cardiac applications using ray-tracing simulations and comparing to independently obtained theoretical derivations. For the flat detector we use parameters close to what we would expect the new multi-pinhole GE Discovery system. We show that using a paraboloid detector we can obtain sensitivity gains as much as ∼2.25 for similar resolutions as a flat detector by opening the pinhole diameter more or we could obtain a better resolution system (∼30% better on the average) by keeping same pinhole opening. Thus far we compared the effect of pinhole and have not included the intrinsic resolution yet.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"11 1","pages":"2777-2787"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2010.5874299","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

SPECT is primarily used in the clinic for cardiac myocardial perfusion imaging (MPI). However, for SPECT, sensitivity is impaired due to the need for collimation. System resolution is poor as well. In this work we demonstrate the advantages of curved detector over a flat detector on a pinhole for cardiac applications using ray-tracing simulations and comparing to independently obtained theoretical derivations. For the flat detector we use parameters close to what we would expect the new multi-pinhole GE Discovery system. We show that using a paraboloid detector we can obtain sensitivity gains as much as ∼2.25 for similar resolutions as a flat detector by opening the pinhole diameter more or we could obtain a better resolution system (∼30% better on the average) by keeping same pinhole opening. Thus far we compared the effect of pinhole and have not included the intrinsic resolution yet.
高性能心脏SPECT相机:分辨率和灵敏度模拟
SPECT主要用于临床心肌灌注成像(MPI)。然而,对于SPECT,由于需要准直,灵敏度受到损害。系统分辨率也很差。在这项工作中,我们通过射线追踪模拟和独立获得的理论推导,证明了在心脏应用针孔上弯曲探测器比平面探测器的优势。对于平面探测器,我们使用的参数接近于我们期望的新的多针孔GE Discovery系统。我们表明,使用抛物面探测器,通过打开更多针孔直径,我们可以获得与平面探测器相似分辨率的灵敏度增益高达~ 2.25,或者通过保持相同的针孔开口,我们可以获得更好的分辨率系统(平均提高~ 30%)。到目前为止,我们比较了针孔的影响,还没有包括固有分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信