{"title":"Spectral broadening in conventional and harmonic Doppler measurements with gaseous contrast agents","authors":"W. Shi, F. Forsberg, H. Oung","doi":"10.1109/ULTSYM.1997.663297","DOIUrl":null,"url":null,"abstract":"Gaseous contrast agents can be used to enhance conventional Doppler measurements and to create new harmonic Doppler modalities. The effect of bubble destruction on both conventional and harmonic Doppler spectra was studied using an in vitro, pulsatile flow system. Similar spectrograms were observed for low levels of insonification (below 0.62 MPa) in both conventional and harmonic Doppler measurements of the same flow. As the acoustic output was increased (up to 1.8 MPa) the spectrograms showed marked spectral broadening, especially for harmonic Doppler. The spectral broadening was caused by transit time effects resulting from the destruction of insonated bubbles. This finding was confirmed by performing a similar experiment on stationary polymer-coated microbubbles suspended in a gel phantom. In conclusion, the effect of bubble destruction should be taken into account in both conventional and harmonic Doppler measurements with gaseous contrast agents.","PeriodicalId":6369,"journal":{"name":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","volume":"3 1","pages":"1575-1578 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1997.663297","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

Gaseous contrast agents can be used to enhance conventional Doppler measurements and to create new harmonic Doppler modalities. The effect of bubble destruction on both conventional and harmonic Doppler spectra was studied using an in vitro, pulsatile flow system. Similar spectrograms were observed for low levels of insonification (below 0.62 MPa) in both conventional and harmonic Doppler measurements of the same flow. As the acoustic output was increased (up to 1.8 MPa) the spectrograms showed marked spectral broadening, especially for harmonic Doppler. The spectral broadening was caused by transit time effects resulting from the destruction of insonated bubbles. This finding was confirmed by performing a similar experiment on stationary polymer-coated microbubbles suspended in a gel phantom. In conclusion, the effect of bubble destruction should be taken into account in both conventional and harmonic Doppler measurements with gaseous contrast agents.
气体造影剂在常规和谐波多普勒测量中的光谱展宽
气体造影剂可以用来增强传统的多普勒测量和创建新的谐波多普勒模式。利用体外脉冲流系统研究了气泡破坏对常规和谐波多普勒频谱的影响。在相同流量的常规多普勒测量和谐波多普勒测量中,在低水平的失谐(低于0.62 MPa)下观察到类似的频谱图。随着声输出增大(达到1.8 MPa),谱图显示出明显的谱宽,尤其是谐波多普勒谱。光谱展宽是由气泡破坏引起的透射时间效应引起的。这一发现被一个类似的实验证实,实验对象是悬浮在凝胶幻影中的固定聚合物包覆微泡。总之,在用气体造影剂进行常规和谐波多普勒测量时都应考虑气泡破坏的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信