Analysis of Co(II) Concentration Using Cyclic Voltammetry Technique

Shynta Ramadhan, Gayatri Citra Dewi
{"title":"Analysis of Co(II) Concentration Using Cyclic Voltammetry Technique","authors":"Shynta Ramadhan, Gayatri Citra Dewi","doi":"10.56425/cma.v1i3.45","DOIUrl":null,"url":null,"abstract":"Cobalt (Co), as one of the toxic and non-biodegradable heavy metals, has polluted most of the waters, which has an impact on human health and biotic components. Currently, the electrochemical method as a fast, accurate, and reliable technique for detecting heavy metals has been widely developed. Therefore, to obtain results with high accuracy, it is necessary to carry out the analysis under conditions suitable for the heavy metal to be analyzed. In this study, several parameters of Co metal content analysis, such as voltage range, scan rate, and pH were examined using the cyclic voltammetry technique. Metal content analysis using atomic absorption spectrometry was also carried out as a comparison. Based on the results of the analysis of Co metal in the waste solution, it shows that the measurement conditions for the analysis of Co(II) metal are each with a voltage range of 0.75 V to -1.5 V, a scan rate of 200 mV/s, and a pH of 7. The detection limit and quantization limit of Co(II) standard solution are 217.06 mg/L and 723.5 mg/L, respectively, with an RSD of 0.9% and a validity value of the correlation coefficient of 0.9992.","PeriodicalId":9724,"journal":{"name":"chemistry and materials research","volume":"17 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"chemistry and materials research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56425/cma.v1i3.45","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Cobalt (Co), as one of the toxic and non-biodegradable heavy metals, has polluted most of the waters, which has an impact on human health and biotic components. Currently, the electrochemical method as a fast, accurate, and reliable technique for detecting heavy metals has been widely developed. Therefore, to obtain results with high accuracy, it is necessary to carry out the analysis under conditions suitable for the heavy metal to be analyzed. In this study, several parameters of Co metal content analysis, such as voltage range, scan rate, and pH were examined using the cyclic voltammetry technique. Metal content analysis using atomic absorption spectrometry was also carried out as a comparison. Based on the results of the analysis of Co metal in the waste solution, it shows that the measurement conditions for the analysis of Co(II) metal are each with a voltage range of 0.75 V to -1.5 V, a scan rate of 200 mV/s, and a pH of 7. The detection limit and quantization limit of Co(II) standard solution are 217.06 mg/L and 723.5 mg/L, respectively, with an RSD of 0.9% and a validity value of the correlation coefficient of 0.9992.
循环伏安法分析Co(II)浓度
钴(Co)作为一种有毒且不可生物降解的重金属,污染了大部分水域,对人类健康和生物成分产生了影响。目前,电化学方法作为一种快速、准确、可靠的重金属检测技术得到了广泛的发展。因此,为了获得高精度的结果,有必要在适合待分析重金属的条件下进行分析。在本研究中,使用循环伏安法检测了几个参数,如电压范围、扫描速率和pH。并采用原子吸收光谱法进行了金属含量分析。根据废溶液中Co金属的分析结果,分析Co(II)金属的测量条件为:电压范围0.75 V ~ -1.5 V,扫描速率200 mV/s, pH = 7。Co(II)标准溶液的检出限和定量限分别为217.06 mg/L和723.5 mg/L, RSD为0.9%,相关系数的效度为0.9992。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信