A robust delineation approach of electrocardiographic P waves

Y. Singh, Phalguni Gupta
{"title":"A robust delineation approach of electrocardiographic P waves","authors":"Y. Singh, Phalguni Gupta","doi":"10.1109/ISIEA.2009.5356341","DOIUrl":null,"url":null,"abstract":"This paper presents a new delineation approach of electrocardiographic P waves. The approach works directly on the digitized ECG. It computes the time derivative of the signal and detects the features of P wave using adaptive thresholding approach that overcome from the impact of high frequency noise present in the signal. Performance of the proposed P wave delineator is evaluated on Physionet QT database, which shows the detection sensitivity to 99.5% and positive predictivity to 99.89%. Lower values of mean error and standard deviation for onset and offset of P wave fiducials are obtained to 5.18±8.1 and 4.4±6.29, where units are in ms. These delineation results are outperformed in comparison to other methods on standard database.","PeriodicalId":6447,"journal":{"name":"2009 IEEE Symposium on Industrial Electronics & Applications","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE Symposium on Industrial Electronics & Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIEA.2009.5356341","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

This paper presents a new delineation approach of electrocardiographic P waves. The approach works directly on the digitized ECG. It computes the time derivative of the signal and detects the features of P wave using adaptive thresholding approach that overcome from the impact of high frequency noise present in the signal. Performance of the proposed P wave delineator is evaluated on Physionet QT database, which shows the detection sensitivity to 99.5% and positive predictivity to 99.89%. Lower values of mean error and standard deviation for onset and offset of P wave fiducials are obtained to 5.18±8.1 and 4.4±6.29, where units are in ms. These delineation results are outperformed in comparison to other methods on standard database.
一种稳健的心电图P波描绘方法
本文提出了一种新的心电图P波圈定方法。该方法直接适用于数字化心电。它计算信号的时间导数,并使用自适应阈值方法检测P波的特征,该方法克服了信号中存在的高频噪声的影响。在Physionet QT数据库上对所提出的P波描述器的性能进行了评估,检测灵敏度为99.5%,阳性预测率为99.89%。P波基准点起始和偏移的平均误差和标准差较低,分别为5.18±8.1和4.4±6.29,单位为ms。与标准数据库上的其他方法相比,其圈定结果优于其他方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信