Flexometallic versus RAE Endotracheal Tube in Cleft Lip and Palate Surgery

Jyoti M. Naitam, N. G. Tirpude
{"title":"Flexometallic versus RAE Endotracheal Tube in Cleft Lip and Palate Surgery","authors":"Jyoti M. Naitam, N. G. Tirpude","doi":"10.7439/IJBAR.V9I5.4775","DOIUrl":null,"url":null,"abstract":"Aim and Objectives: The present study was carried out with an objective to evaluate ease of insertion of catheter and suctioning through Flexo-metallic tube versus Ring Adair Elwin (RAE) tube, to know the incidence of kinking of RAE tube and to note down the endo-bronchial placement of Flexo-metallic versus RAE tube and surgeon’s comfort zone. Methods: A prospective observational randomized study was conducted on 60 ASA grade I and II pediatric patients of age group 4 month to 16 years undergoing cleft lip and palate surgeries. Patients were randomly allocated in two groups of 30 each. Group R: intubated with RAE South pole tube and group F: intubated with flexo-metallic tube. The ease of insertion of suction catheter, ease of suctioning of secretions, refixation required, kinking of tracheal tube, incidence of displacement, airway complications and surgeons’ feedback- Comfort zone were noted. Results: The ease of suctioning through lumen of Tracheal tube was easier in group ‘F’ as compared to RAE tube. No kinking of tracheal tube was found in any group. The displacement of tracheal tube was observed in 2 patients in group ‘R’. Refixation of tracheal tube was required in 2 patients in group ‘R’. Bronchospasm and cough was noted in 1 patient in group ‘R’. No variations in vitals (e.g. blood pressure and heart rate) were observed in any group. Surgical team was comfortable in both groups but more so with Flexo-metallic tracheal tube group. On extubation we found retained secretions at distal portion of RAE tube in 2 patients. Conclusion : Flexometallic tracheal tube provides advantage of easy suctioning of tracheal secretions. Do not kink in mouth gag of surgical field, provides better airway security and stability, less intra-operative manipulation by anaesthetist, less airway complications, provides better surgical field.","PeriodicalId":13848,"journal":{"name":"International Journal of Biomedical and Advance Research","volume":"34 1","pages":"195-199"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Biomedical and Advance Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7439/IJBAR.V9I5.4775","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim and Objectives: The present study was carried out with an objective to evaluate ease of insertion of catheter and suctioning through Flexo-metallic tube versus Ring Adair Elwin (RAE) tube, to know the incidence of kinking of RAE tube and to note down the endo-bronchial placement of Flexo-metallic versus RAE tube and surgeon’s comfort zone. Methods: A prospective observational randomized study was conducted on 60 ASA grade I and II pediatric patients of age group 4 month to 16 years undergoing cleft lip and palate surgeries. Patients were randomly allocated in two groups of 30 each. Group R: intubated with RAE South pole tube and group F: intubated with flexo-metallic tube. The ease of insertion of suction catheter, ease of suctioning of secretions, refixation required, kinking of tracheal tube, incidence of displacement, airway complications and surgeons’ feedback- Comfort zone were noted. Results: The ease of suctioning through lumen of Tracheal tube was easier in group ‘F’ as compared to RAE tube. No kinking of tracheal tube was found in any group. The displacement of tracheal tube was observed in 2 patients in group ‘R’. Refixation of tracheal tube was required in 2 patients in group ‘R’. Bronchospasm and cough was noted in 1 patient in group ‘R’. No variations in vitals (e.g. blood pressure and heart rate) were observed in any group. Surgical team was comfortable in both groups but more so with Flexo-metallic tracheal tube group. On extubation we found retained secretions at distal portion of RAE tube in 2 patients. Conclusion : Flexometallic tracheal tube provides advantage of easy suctioning of tracheal secretions. Do not kink in mouth gag of surgical field, provides better airway security and stability, less intra-operative manipulation by anaesthetist, less airway complications, provides better surgical field.
柔性金属与RAE气管插管在唇腭裂手术中的应用
目的与目的:本研究的目的是评价Flexo-metallic tube与Ring Adair Elwin (RAE) tube的导管插入和吸引的易感性,了解RAE tube扭结的发生率,记录Flexo-metallic tube与RAE tube的支气管内放置和外科医生的舒适区。方法:对60例年龄为4个月~ 16岁的ASA I级和II级患儿进行前瞻性观察性随机研究。患者被随机分为两组,每组30人。R组采用RAE南极管插管,F组采用柔性金属管插管。观察吸入导管插入难易程度、分泌物吸出难易程度、需要重新固定、气管管扭结、移位发生率、气道并发症及外科医生反馈的舒适区情况。结果:与RAE管相比,F组气管管腔吸痰容易。两组均未见气管管扭结。R组2例出现气管管移位。R组2例患者需重新固定气管管。R组1例出现支气管痉挛和咳嗽。在任何组中都没有观察到生命体征(如血压和心率)的变化。两组手术组均舒适,但柔性金属气管插管组舒适程度更高。在拔管时,我们发现2例患者在RAE管远端部分保留分泌物。结论:柔性金属气管管具有方便吸出气管分泌物的优点。手术野口不打结,提供更好的气道安全性和稳定性,术中麻醉师操作少,气道并发症少,提供更好的手术野。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信