{"title":"Development and Validation of RP-HPLC Method with Diode Array Detection for Estimation of Metaxalone in Rat Plasma","authors":"I. Rizwana, K. Prakash, G. Mohan","doi":"10.5530/PHM.2014.2.4","DOIUrl":null,"url":null,"abstract":"Purpose: To develop a simple, highly sensitive, precise and accurate high-performance liquid chromatographic method with photodiode array detection and validated for the rapid quantification of metaxalone in rat plasma samples. Method: Following Liquid-Liquid Extraction (LLE), metaxalone and the internal standard Phenytoin (PHY) were extracted from an aliquot of 200 mL of plasma. Chromatographic separation was carried out using Phenomenex Luna C 8 column (250 mmμ 4.6 mmμ 5 mm) with mobile phase composed of phosphate buffer, pH 7 and acetonitrile in 35:65, v/v ratio. The analyte was monitored with UV detector at 219 nm. The developed method was validated with respect to linearity, accuracy, precision, specificity and stability. The peak area ratio of MET to that of internal standard, PHY was used for the quantification of samples. Results: The retention time of MET and PHY were found to be 2.30 and 3.02 min respectively. The calibration curve was linear (r 2 > or=0.99) ranging from 1.505-538.254 ng/ml and the lower limit of quantification was 1.505 ng/mL. Interday and Intraday precision were lower than 5% (CV) and accuracy ranged from 95 to 105% in terms of percent accuracy. Mean extraction recovery was found to be above 94%. Conclusion: A simple, alternative, reproducible and sensitive HPLC-DAD method was developed for MET that can be used in preclinical pharmacokinetics. Key words: Ammonium formate buffer, Acetonitrile, Metaxalone, Phenytoin, Preclinical pharmacokinetics.","PeriodicalId":19960,"journal":{"name":"Pharmaceutical Methods","volume":"18 1","pages":"61"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutical Methods","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5530/PHM.2014.2.4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: To develop a simple, highly sensitive, precise and accurate high-performance liquid chromatographic method with photodiode array detection and validated for the rapid quantification of metaxalone in rat plasma samples. Method: Following Liquid-Liquid Extraction (LLE), metaxalone and the internal standard Phenytoin (PHY) were extracted from an aliquot of 200 mL of plasma. Chromatographic separation was carried out using Phenomenex Luna C 8 column (250 mmμ 4.6 mmμ 5 mm) with mobile phase composed of phosphate buffer, pH 7 and acetonitrile in 35:65, v/v ratio. The analyte was monitored with UV detector at 219 nm. The developed method was validated with respect to linearity, accuracy, precision, specificity and stability. The peak area ratio of MET to that of internal standard, PHY was used for the quantification of samples. Results: The retention time of MET and PHY were found to be 2.30 and 3.02 min respectively. The calibration curve was linear (r 2 > or=0.99) ranging from 1.505-538.254 ng/ml and the lower limit of quantification was 1.505 ng/mL. Interday and Intraday precision were lower than 5% (CV) and accuracy ranged from 95 to 105% in terms of percent accuracy. Mean extraction recovery was found to be above 94%. Conclusion: A simple, alternative, reproducible and sensitive HPLC-DAD method was developed for MET that can be used in preclinical pharmacokinetics. Key words: Ammonium formate buffer, Acetonitrile, Metaxalone, Phenytoin, Preclinical pharmacokinetics.
二极管阵列反相高效液相色谱法测定大鼠血浆中甲他龙含量的建立与验证
目的:建立一种简便、灵敏、精确、准确的光电二极管阵列高效液相色谱检测方法,用于大鼠血浆样品中甲他龙的快速定量。方法:采用液-液萃取法(LLE),分别从200 mL血浆中提取甲他龙和内标苯妥英(PHY)。色谱柱为Phenomenex Luna c8 (250 mmμ 4.6 mmμ 5 mm),流动相为磷酸缓冲液,pH为7,乙腈为35:65,v/v比。用紫外检测器在219 nm处监测分析物。对该方法进行了线性度、准确度、精密度、专属性和稳定性验证。采用MET与内标、PHY的峰面积比对样品进行定量。结果:MET和PHY的滞留时间分别为2.30 min和3.02 min。校正曲线在1.505 ~ 538.254 ng/ml范围内呈线性(r =0.99或r= 2bb0),定量下限为1.505 ng/ml。日间和日内精度低于5% (CV),准确度范围为95%至105%。平均提取回收率在94%以上。结论:建立了一种简便、可替代、重现性好、灵敏度高的MET检测方法,可用于临床前药动学分析。关键词:甲酸铵缓冲液,乙腈,甲他龙,苯妥英,临床前药代动力学
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信