Yasuhiko Kobayashi, M. Fukuda, S. Sakaguchi, Y. Nakao, K. Nishimine
{"title":"Custom Made Fenestrated Stent Graft Collapse after Thoracic Endovascular Aortic Repair: A Case Report","authors":"Yasuhiko Kobayashi, M. Fukuda, S. Sakaguchi, Y. Nakao, K. Nishimine","doi":"10.4236/crcm.2023.128042","DOIUrl":null,"url":null,"abstract":"We performed thoracic endovascular aortic repair with a custom-made fenestrated stent graft and present a case of stent graft collapse after thoracic endovascular aortic repair. The pa-tient was a 70-year-old woman with an asymptomatic aneurysm of the distal aortic arch, and thoracic endovascular aortic repair was performed with a custom-made fenestrated stent graft. The patient showed a blood pressure difference between the left and right arms on postoperative day (POD) 17 prompting per-formance of a chest computed tomographys can which revealed stent graft collapse. She then underwent staged debranching thoracic endovascular aortic repair. Stent graft collapse is a rare but well-described complication of thoracic endovascular repair. Therefore, patients who undergo such a procedure should be carefully monitored for signs and symptoms, which suggest the possibility of stent collapse.","PeriodicalId":9618,"journal":{"name":"Case Reports in Clinical Medicine","volume":"34 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Reports in Clinical Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/crcm.2023.128042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
We performed thoracic endovascular aortic repair with a custom-made fenestrated stent graft and present a case of stent graft collapse after thoracic endovascular aortic repair. The pa-tient was a 70-year-old woman with an asymptomatic aneurysm of the distal aortic arch, and thoracic endovascular aortic repair was performed with a custom-made fenestrated stent graft. The patient showed a blood pressure difference between the left and right arms on postoperative day (POD) 17 prompting per-formance of a chest computed tomographys can which revealed stent graft collapse. She then underwent staged debranching thoracic endovascular aortic repair. Stent graft collapse is a rare but well-described complication of thoracic endovascular repair. Therefore, patients who undergo such a procedure should be carefully monitored for signs and symptoms, which suggest the possibility of stent collapse.