A New Standard Radiator For Shielding Effectiveness Measurements

B. Archambeault, M. Seth
{"title":"A New Standard Radiator For Shielding Effectiveness Measurements","authors":"B. Archambeault, M. Seth","doi":"10.1109/ISEMC.1992.626090","DOIUrl":null,"url":null,"abstract":"The lack of a standard emission source make shielding effectiveness measurements difficult to perform with any degree of repeatability. This lack of repeatability tends to make EM1 engineers reluctant to place too much reliance on shielding effectiveness measurements. This paper describes a new standard radiator that can be used in making shielding effectiveness measurements that are repeatable. This source is physically small, battery powered, and operates over a frequency range of 10 MHz to >1 GHz. The radiator produces a standard dipole radiation pattern, and radiates sufficient energy to test most shielded enclosures. Introduction The need to predict the performance of an EM1 shielded device has become more important than ever. As the speed of computers and other devices increase, existing 'rule-of-thumb' shielding designs are no longer sufficient. Traditional methods to quantify the effectiveness of designs to control EM1 are becoming outmoded. One of the major contributors to this problem is measuring the performance of shielded enclosures or boxes. It is becoming accepted throughout the industry that shielding effectiveness measurements have limited use. However, shielding effectiveness measurements continue to be used by many people as a measure of 'goodness' of a particular shielded enclosure or box. This paper will describe a new standard source that may be used in evaluating the shielding effectiveness of enclosures. It will also discuss some of the problems associated with shielding effectiveness measurements and show how this new radiator improves the the repeatability of measurements. This new standard radiator was developed 'ointly between the National Institute of Standards and Tecknology (NIST), the U.S. Navy, and Digital Equipment Corporation. This new radiator is physically small (IO cm diameter), battery operated, operates over a frequency range of 10 MHz to above 1 GHz, and has no metal connection between the radiator element and the control unit. Di ita1 has successfully used this radiator to correlate the &AI performance changes with enclosure modifications, for both large and small enclosures. Shieldina Effectiveness The term 'Shielding Effectiveness' is commonly misused by most engineers and managers. Shielding effectiveness is really a relative term, having meaning only when Mark Seth Seth Industries, Inc. two similar constructions are compared. Unfortunately, they have become very familiar with the term, and they feel very comfortable using shielding effectiveness values without considering the difference between the tested configuration and the target configuration. It is not uncommon for an engineer to measure the radiation from a particular circuit board, note the difference between the received level and the desired limit, and decide on the number of dB of shielding effectiveness needed to meet the desired limit. Since the presence of the shield will change the radiation source characteristics, and since the shielding effectiveness value was determined from a different type test, the expected result may not be realized. Most shielding effectiveness values are created using a far field Electromagnetic (EM) source. This is fine for radar applications, but typical computer shielding applications have EM sources in the near field. The interaction between the source and shielding panel (when in the near field) cannot be ignored if reasonably accurate results are desired. All equations, graphs, etc. are also created from far field configurations, a ain resulting in inaccurate results when applied to reayistic shielding.problems. Since the EM source will be changed due to the presence of the shield, the shielding effectiveness test must include this effect, or any test results will be merely a comparison of 'apples and oranges'. Naturally, it is valid to compare various shielding options when the actual source is used, became then the final result is based upon the true configuration. Comparison between 'option A and 'option B will show a relative difference between the shielding effectiveness of the two options. A better term for this comparison test might be \"Shielding Performance.\" In spite of all the problems associated with shielding effectiveness measurements, they still remain useful to the design engineer. When a particular shielded enclosure will be used for a given computer, etc., then design decisions must often be made concerning design trade-offs. However, extreme care must be taken when making these design decisions, since often the test results are more a measure of the test setup than the true shielding effectiveness. Shieldina Effectiveness Tests The problems inherent in shielding effectiveness tests of enclosures, cabinets, and boxes are well known throughout the industry. A few of the most critical problems will be repeated here. 1. The test set up is critical, and often a slight change in source position will cause the results to vary wildly. CH3169-0/92/0000-0052 $3.00 01992 IEEE 256 2. If the radiating antenna is too large, then the interaction between the shield and the antenna (effectively loading the antenna) will cause large differences between the a.mount of energy delivered to the antenna and the expected value. 3. The coax cable traveling from the enclosure to the shielded test room wall (or generator) can 'leak', resulting in reduced effective Shielding effectiveness. 41. Typically, the wrong radiating source is used. Some configurations would use a horn antenna as the source, but the actual source of EM1 is seldom as well behaved as i i plane wave. Some configurations used a wire strung within the enclosure as the soiurce, but no concern was given the the 'antenna' impedance, and so the actual energy launched by this antenna would vary dramatically as a function of frequency. E;. Some configurations required a large RF generator be placed within the enclosure, making this setup impractical f'or anything smaller than a full cabinet. Many configurations were so sensitive to the physical setup within the enc:losure, that results could not be duplicated. All these factors made EM1 engineers reluctant to use the shielding effectiveness test results with a high degree of confidence. These problems can be overcome, but the source must be physically small, electrically isolated, and electromagnetically well behaved. Such a source exists, and should be used as the general shielding effectiveness source when testing shielded cabinets, enclosures, and boxes. !standard Dipole Radiator Description The Standard Dipole Radiator (SDR) is a physically small (1 0 cm) s herical source that is electrically isolated. Many of t l e problems associated with typical radiating sources are eliminated when using the SDR. The SDR !System is depicted in Figures 1 & 2 and consists of: 41 The Sphere (antenna) 4) The Control Unit o Interconnecting Fiber Optic Cables 'The Sphere is the radiating element or antenna. Circuitry ;and power sources for developing the standard field are contained within the sphere's core. The control unit supplies the sphere with a modulated laser signal and provides monitor readouts. The control unit is connected to the sphere by fiber optic cables which provides electrical iisolation between the sphere and control unit. Figure 3 shows the block diagram of the SDR System.","PeriodicalId":93568,"journal":{"name":"IEEE International Symposium on Electromagnetic Compatibility : [proceedings]. IEEE International Symposium on Electromagnetic Compatibility","volume":"1 1","pages":"256-265"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE International Symposium on Electromagnetic Compatibility : [proceedings]. IEEE International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1992.626090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The lack of a standard emission source make shielding effectiveness measurements difficult to perform with any degree of repeatability. This lack of repeatability tends to make EM1 engineers reluctant to place too much reliance on shielding effectiveness measurements. This paper describes a new standard radiator that can be used in making shielding effectiveness measurements that are repeatable. This source is physically small, battery powered, and operates over a frequency range of 10 MHz to >1 GHz. The radiator produces a standard dipole radiation pattern, and radiates sufficient energy to test most shielded enclosures. Introduction The need to predict the performance of an EM1 shielded device has become more important than ever. As the speed of computers and other devices increase, existing 'rule-of-thumb' shielding designs are no longer sufficient. Traditional methods to quantify the effectiveness of designs to control EM1 are becoming outmoded. One of the major contributors to this problem is measuring the performance of shielded enclosures or boxes. It is becoming accepted throughout the industry that shielding effectiveness measurements have limited use. However, shielding effectiveness measurements continue to be used by many people as a measure of 'goodness' of a particular shielded enclosure or box. This paper will describe a new standard source that may be used in evaluating the shielding effectiveness of enclosures. It will also discuss some of the problems associated with shielding effectiveness measurements and show how this new radiator improves the the repeatability of measurements. This new standard radiator was developed 'ointly between the National Institute of Standards and Tecknology (NIST), the U.S. Navy, and Digital Equipment Corporation. This new radiator is physically small (IO cm diameter), battery operated, operates over a frequency range of 10 MHz to above 1 GHz, and has no metal connection between the radiator element and the control unit. Di ita1 has successfully used this radiator to correlate the &AI performance changes with enclosure modifications, for both large and small enclosures. Shieldina Effectiveness The term 'Shielding Effectiveness' is commonly misused by most engineers and managers. Shielding effectiveness is really a relative term, having meaning only when Mark Seth Seth Industries, Inc. two similar constructions are compared. Unfortunately, they have become very familiar with the term, and they feel very comfortable using shielding effectiveness values without considering the difference between the tested configuration and the target configuration. It is not uncommon for an engineer to measure the radiation from a particular circuit board, note the difference between the received level and the desired limit, and decide on the number of dB of shielding effectiveness needed to meet the desired limit. Since the presence of the shield will change the radiation source characteristics, and since the shielding effectiveness value was determined from a different type test, the expected result may not be realized. Most shielding effectiveness values are created using a far field Electromagnetic (EM) source. This is fine for radar applications, but typical computer shielding applications have EM sources in the near field. The interaction between the source and shielding panel (when in the near field) cannot be ignored if reasonably accurate results are desired. All equations, graphs, etc. are also created from far field configurations, a ain resulting in inaccurate results when applied to reayistic shielding.problems. Since the EM source will be changed due to the presence of the shield, the shielding effectiveness test must include this effect, or any test results will be merely a comparison of 'apples and oranges'. Naturally, it is valid to compare various shielding options when the actual source is used, became then the final result is based upon the true configuration. Comparison between 'option A and 'option B will show a relative difference between the shielding effectiveness of the two options. A better term for this comparison test might be "Shielding Performance." In spite of all the problems associated with shielding effectiveness measurements, they still remain useful to the design engineer. When a particular shielded enclosure will be used for a given computer, etc., then design decisions must often be made concerning design trade-offs. However, extreme care must be taken when making these design decisions, since often the test results are more a measure of the test setup than the true shielding effectiveness. Shieldina Effectiveness Tests The problems inherent in shielding effectiveness tests of enclosures, cabinets, and boxes are well known throughout the industry. A few of the most critical problems will be repeated here. 1. The test set up is critical, and often a slight change in source position will cause the results to vary wildly. CH3169-0/92/0000-0052 $3.00 01992 IEEE 256 2. If the radiating antenna is too large, then the interaction between the shield and the antenna (effectively loading the antenna) will cause large differences between the a.mount of energy delivered to the antenna and the expected value. 3. The coax cable traveling from the enclosure to the shielded test room wall (or generator) can 'leak', resulting in reduced effective Shielding effectiveness. 41. Typically, the wrong radiating source is used. Some configurations would use a horn antenna as the source, but the actual source of EM1 is seldom as well behaved as i i plane wave. Some configurations used a wire strung within the enclosure as the soiurce, but no concern was given the the 'antenna' impedance, and so the actual energy launched by this antenna would vary dramatically as a function of frequency. E;. Some configurations required a large RF generator be placed within the enclosure, making this setup impractical f'or anything smaller than a full cabinet. Many configurations were so sensitive to the physical setup within the enc:losure, that results could not be duplicated. All these factors made EM1 engineers reluctant to use the shielding effectiveness test results with a high degree of confidence. These problems can be overcome, but the source must be physically small, electrically isolated, and electromagnetically well behaved. Such a source exists, and should be used as the general shielding effectiveness source when testing shielded cabinets, enclosures, and boxes. !standard Dipole Radiator Description The Standard Dipole Radiator (SDR) is a physically small (1 0 cm) s herical source that is electrically isolated. Many of t l e problems associated with typical radiating sources are eliminated when using the SDR. The SDR !System is depicted in Figures 1 & 2 and consists of: 41 The Sphere (antenna) 4) The Control Unit o Interconnecting Fiber Optic Cables 'The Sphere is the radiating element or antenna. Circuitry ;and power sources for developing the standard field are contained within the sphere's core. The control unit supplies the sphere with a modulated laser signal and provides monitor readouts. The control unit is connected to the sphere by fiber optic cables which provides electrical iisolation between the sphere and control unit. Figure 3 shows the block diagram of the SDR System.
屏蔽效能测量的新标准辐射器
Ch3169-0/92/0000-0052 $3.00 01992 ieee 256如果辐射天线太大,那么屏蔽和天线之间的相互作用(有效加载天线)将导致传递到天线的能量与期望值之间的巨大差异。3.从外壳到屏蔽测试室墙壁(或发电机)的同轴电缆可能“泄漏”,导致有效屏蔽效果降低。41. 通常,使用了错误的辐射源。一些配置将使用喇叭天线作为源,但EM1的实际源很少表现得像平面波一样好。一些配置使用电线串在外壳内作为源,但没有考虑到“天线”的阻抗,所以这个天线发射的实际能量作为频率的函数会有很大的变化。E;。有些配置需要在外壳内放置一个大型射频发生器,这使得这种设置对于小于完整机柜的任何东西都不切实际。许多配置对enc: closed中的物理设置非常敏感,结果无法复制。所有这些因素使得EM1工程师不愿意高度自信地使用屏蔽效能测试结果。这些问题都是可以克服的,但是源必须物理上小,电隔离,并且电磁性能良好。这种源是存在的,在测试屏蔽机柜、外壳和盒子时,应将其作为通用屏蔽效能源。标准偶极子散热器(standard Dipole Radiator, SDR)是一种小尺寸(10cm)的电隔离源。当使用SDR时,与典型辐射源相关的许多问题都被消除了。SDR系统如图1和图2所示,由以下部分组成:41球体(天线)4)连接光纤电缆的控制单元球体是辐射元件或天线。用于发展标准场的电路和电源包含在球体的核心中。控制单元为球体提供调制激光信号并提供监视器读数。控制单元通过光纤电缆连接到球体,光纤电缆在球体和控制单元之间提供电气隔离。图3显示了SDR系统的框图。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.30
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信